EUVIMEDEUVIMED entdecken
Crossref

Evaluation of Adjoint-Optimized Holes—Part I Baseline Performance

Daniel Gutierrez, Christopher Yoon, Michael T. Furgeson, Emma M. Veley, David G. Bogard, Karen A. Thole

Journal of Turbomachinery · 01.11.2024 · 146 (11)

DOI: 10.1115/1.4056390 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Turbomachinery, online erschienen am 27.06.2024. Verfasst von Daniel Gutierrez und 5 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: U.S. Department of Energy.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the advent of the use of additive manufacturing to build gas turbine components, the design space for new hole geometries is essentially unlimited. Recently, a computational adjoint-based optimization method was used to design shaped film cooling holes fed by internal co-flow and cross-flow channels. The associated Reynolds-averaged Navier–Stokes computations predicted that the holes optimized for use with cross-flow (X-AOpt) and co-flow (Co-AOpt) would significantly increase adiabatic effectiveness. However, only the X-AOpt hole was tested experimentally in this previous study. Though the experimentally measured performance for this hole was much less than computationally predicted, it still had a 75% improved performance compared to the conventional 7-7-7-shaped hole. In the current study, the X-AOpt and Co-AOpt-shaped holes were experimentally evaluated using measurements of adiabatic effectiveness and overall cooling effectiveness. Coolant was fed to the holes with an internal co-flow channel. For reference, experiments were also conducted with the baseline 7-7-7-shaped hole, and a 15-15-1-shaped hole (shown in a previous study to be the optimum expansion angles for a shaped hole). Furthermore, overall cooling effectiveness measurements were made with engine-scale models to evaluate the performance of additively manufactured (AM) X-AOpt and Co-AOpt holes with a realistic metal build. Results from this study confirmed that the X-AOpt hole had a 75% increase in adiabatic effectiveness compared to the 7-7-7-shaped hole. However, the Co-AOpt hole had only a 30% increase in adiabatic effectiveness, substantially less than had been computationally predicted. Measurements of overall cooling effectiveness for the engine-scale models and the large-scale models followed similar trends.

Förderung

  • U.S. Department of Energy

Zitieren

APA

Gutierrez, D., Yoon, C., Furgeson, M. T., Veley, E. M., Bogard, D. G., & Thole, K. A. (2024). Evaluation of Adjoint-Optimized Holes—Part I Baseline Performance. Journal of Turbomachinery, 146(11). https://doi.org/10.1115/1.4056390

Vancouver

Gutierrez D, Yoon C, Furgeson MT, Veley EM, Bogard DG, Thole KA. Evaluation of Adjoint-Optimized Holes—Part I Baseline Performance. Journal of Turbomachinery. 2024;146(11). doi:10.1115/1.4056390

BibTeX
@article{Gutierrez2024,
  author = {Gutierrez, Daniel and Yoon, Christopher and Furgeson, Michael T. and Veley, Emma M. and Bogard, David G. and Thole, Karen A.},
  title = {Evaluation of Adjoint-Optimized Holes—Part I Baseline Performance},
  journal = {Journal of Turbomachinery},
  year = {2024},
  volume = {146},
  number = {11},
  doi = {10.1115/1.4056390}
}