From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves
Journal of Biomechanical Engineering · 2023
DOI: 10.1115/1.4056353 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2023. Verfasst von Aeryne Lee und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemical and Biomolecular Engineering, The University of Sydney, Darlington, NSW 2008, Australia; School of Medicine, The University of Syd…. Hauptthemen laut MEDLINE: Heart Valve Prosthesis. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Current heart valve replacements lack durability and prolonged performance, especially in pediatric patients. In part, these problems may be attributed to the materials chosen for these constructs, but another important contributing factor is the design of the valve, as this dictates hemodynamic performance and impacts leaflet stresses which may accelerate structural valve deterioration. Most current era bioprosthetic valves adhere to a fundamental design where flat leaflets are supported by commissural posts, secured to a sewing ring. This overall design strategy is effective, but functionality and durability can be improved by incorporating features of the native valve geometry. This paper presents a novel workflow for developing and analyzing bio-inspired valve designs computationally. The leaflet curvature was defined using a mathematical equation whose parameters were derived from the three-dimensional model of a native sheep pulmonary valve obtained via microcomputed tomography. Finite element analysis was used to screen the various valve designs proposed in this study by assessing the effect of leaflet thickness, Young's modulus, and height/curvature on snap-through (where leaflets bend against their original curvature), geometric orifice area (GOA) and the stress in the leaflets. This workflow demonstrated benefits for valve designs with leaflet thicknesses between 0.1 and 0.3 mm, Young's moduli less than 50 MPa, and elongated leaflets with higher curvatures. The proposed workflow brings substantial efficiency gains at the design stage, minimizing manufacturing and animal testing during iterative improvements, and offers a bridge between in vitro and more complex in silico studies in the future.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Chemical and Biomolecular Engineering, The University of Sydney, Darlington, NSW 2008, Australia; School of Medicine, The University of Sydney, Camperdown, NSW 2050, Australia.
- School of Chemical and Biomolecular Engineering, The University of Sydney, Darlington, NSW 2008, Australia; Sydney Nano Institute, The University of Sydney, Camperdown, NSW 2050, Australia.
- School of Chemical and Biomolecular Engineering, The University of Sydney, Darlington, NSW 2008, Australia.
- Leap Australia, Suite 6, 750 Blackburn Road, Clayton North, Victoria 3168, Australia.
- Department of Cardiothoracic Surgery, Heart Institute, Cincinnati Children's Hospital, Cincinnati, OH 45229; School of Medicine, The University of Sydney, Camperdown, NSW 2050, Australia.
Zitieren
APA
Lee, A., Farajikhah, S., Crago, M., Mosse, L., Fletcher, D. F., Dehghani, F., Winlaw, D. S., & Naficy, S. (2023). From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4056353
Vancouver
Lee A, Farajikhah S, Crago M, Mosse L, Fletcher DF, Dehghani F, et al. From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves. Journal of Biomechanical Engineering. 2023. doi:10.1115/1.4056353
BibTeX
@article{Lee2023,
author = {Lee, Aeryne and Farajikhah, Syamak and Crago, Matthew and Mosse, Luke and Fletcher, David Frederick and Dehghani, Fariba and Winlaw, David Scott and Naficy, Sina},
title = {From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves},
journal = {Journal of Biomechanical Engineering},
year = {2023},
doi = {10.1115/1.4056353}
}