Comparison of a Scaled Cadaver-Based Musculoskeletal Model With a Clinical Upper Extremity Model
Journal of Biomechanical Engineering · 01.04.2023 · 145 (4)
DOI: 10.1115/1.4056172 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Biomechanical Engineering, online erschienen am 09.12.2022. Verfasst von Vikranth H Nagaraja und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 3PJ, UK. Hauptthemen laut MEDLINE: Upper Extremity, Musculoskeletal System, Models, Anatomic. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 80 Literaturangaben. Gefördert von: Research Councils UK, Wellcome Trust.
Abstract (Originalsprache)
Reliably and accurately estimating joint/segmental kinematics from optical motion capture data has remained challenging. Studies objectively characterizing human movement patterns have typically involved inverse kinematics and inverse dynamics techniques. Subsequent research has included scaled cadaver-based musculoskeletal (MSK) modeling for noninvasively estimating joint and muscle loads. As one of the ways to enhance confidence in the validity of MSK model predictions, the kinematics from the preceding step that drives such a model needs to be checked for agreement or compared with established/widely used models. This study rigorously compares the upper extremity (UE) joint kinematics calculated by the Dutch Shoulder Model implemented in the AnyBody Managed Model Repository (involving multibody kinematics optimization (MKO)) with those estimated by the Vicon Plug-in Gait model (involving single-body kinematics optimization (SKO)). Ten subjects performed three trials of (different types of) reaching tasks in a three-dimensional marker-based optical motion capture laboratory setting. Joint angles, processed marker trajectories, and reconstruction residuals corresponding to both models were compared. Scatter plots and Bland–Altman plots were used to assess the agreement between the two model outputs. Results showed the largest differences between the two models for shoulder, followed by elbow and wrist, with all root-mean-squared differences less than 10 deg (although this limit might be unacceptable for clinical use). Strong-to-excellent Spearman's rank correlation coefficients were found between the two model outputs. The Bland–Altman plots showed a good agreement between most of the outputs. In conclusion, results indicate that these two models with different kinematic algorithms broadly agree with each other, albeit with few key differences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford OX1 3PJ, UK.
- Department of Materials and Production, Aalborg University, Fibigerstraede 16, Aalborg East DK-9220, Denmark.
Förderung
- Research Councils UK
- Wellcome Trust
Zitieren
APA
Nagaraja, V. H., Bergmann, J. H. M., Andersen, M. S., & Thompson, M. S. (2023). Comparison of a Scaled Cadaver-Based Musculoskeletal Model With a Clinical Upper Extremity Model. Journal of Biomechanical Engineering, 145(4). https://doi.org/10.1115/1.4056172
Vancouver
Nagaraja VH, Bergmann JHM, Andersen MS, Thompson MS. Comparison of a Scaled Cadaver-Based Musculoskeletal Model With a Clinical Upper Extremity Model. Journal of Biomechanical Engineering. 2023;145(4). doi:10.1115/1.4056172
BibTeX
@article{Nagaraja2023,
author = {Nagaraja, Vikranth H and Bergmann, Jeroen H M and Andersen, Michael S and Thompson, Mark S},
title = {Comparison of a Scaled Cadaver-Based Musculoskeletal Model With a Clinical Upper Extremity Model},
journal = {Journal of Biomechanical Engineering},
year = {2023},
volume = {145},
number = {4},
doi = {10.1115/1.4056172}
}