EUVIMEDEUVIMED entdecken
Open Access

Fully Closed Loop Test Environment for Adaptive Implantable Neural Stimulators Using Computational Models

Scott Stanslaski, Hafsa Farooqi, David Escobar Sanabria, Theoden Ivan Netoff

Journal of Medical Devices · 01.09.2022 · 16 (3)

DOI: 10.1115/1.4054083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Devices, online erschienen am 11.04.2022. Verfasst von Scott Stanslaski und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455; Neuromodulation Department, Medtronic PLC, Minneapolis, MN 5543…. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Implantable brain stimulation devices continue to be developed to treat and monitor brain conditions. As the complexity of these devices grows to include adaptive neuromodulation therapy, validating the operation and verifying the correctness of these systems becomes more complicated. The new complexities lie in the functioning of the device being dependent on the interaction with the patient and environmental factors such as noise and artifacts. Here, we present a hardware-in-the-loop (HIL) testing framework that employs computational models of pathological neural dynamics to test adaptive deep brain stimulation (DBS) devices prior to animal or human testing. A brain stimulation and recording electrode array is placed in the saline tank and connected to an adaptive neuromodulation system that measures and processes the synthetic signals and delivers stimulation back into the saline tank. A data acquisition system is used to detect the stimulation and provide feedback to the computational model in order to simulate the effects of stimulation on the neural dynamics. In this study, we used real-time computational models to emulate the dynamics of epileptic seizures observed in the anterior nucleus of the thalamus (ANT) in epilepsy patients and beta band (11–35 Hz) oscillations observed in the subthalamic nucleus (STN) of Parkinson's disease (PD) patients. These models simulated neuronal responses to electrical stimulation pulses and the saline tank tested hardware interactions between the detection algorithms and stimulation interference. We tested and validated the operation of adaptive DBS algorithms for seizure and beta band power suppression embedded in an implantable DBS system (Medtronic Summit RC+S). This study highlights the utility of the proposed hardware-in-the-loop framework to systematically test the adaptive DBS systems in the presence of system aggressors such as environmental noise and stimulation-induced electrical artifacts. This testing procedure can help ensure correctness and robustness of adaptive DBS devices prior to animal and human testing.

Schlagwörter

Stichwörter der Autor:innen

computational modelsneural sensingneural stimulation

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455; Neuromodulation Department, Medtronic PLC, Minneapolis, MN 55432.
  • Department of Neurology, University of Minnesota, Minneapolis, MN 55455.
  • Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN 55455.

Zitieren

APA

Stanslaski, S., Farooqi, H., Sanabria, D. E., & Netoff, T. I. (2022). Fully Closed Loop Test Environment for Adaptive Implantable Neural Stimulators Using Computational Models. Journal of Medical Devices, 16(3). https://doi.org/10.1115/1.4054083

Vancouver

Stanslaski S, Farooqi H, Sanabria DE, Netoff TI. Fully Closed Loop Test Environment for Adaptive Implantable Neural Stimulators Using Computational Models. Journal of Medical Devices. 2022;16(3). doi:10.1115/1.4054083

BibTeX
@article{Stanslaski2022,
  author = {Stanslaski, Scott and Farooqi, Hafsa and Sanabria, David Escobar and Netoff, Theoden Ivan},
  title = {Fully Closed Loop Test Environment for Adaptive Implantable Neural Stimulators Using Computational Models},
  journal = {Journal of Medical Devices},
  year = {2022},
  volume = {16},
  number = {3},
  doi = {10.1115/1.4054083}
}
Kostenlos starten →