Validation of Notch Sensitivity Factors
Journal of Verification, Validation and Uncertainty Quantification · 01.03.2019 · 4 (1)
DOI: 10.1115/1.4044236 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Verification, Validation and Uncertainty Quantification, online erschienen am 02.08.2019. Verfasst von Barna Szabó und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
An end-to-end example of the application of the procedures of verification, validation, and uncertainty quantification (VVUQ) is presented with reference to mathematical models formulated for the prediction of fatigue failure in the high cycle range. A validation metric based on the log likelihood function is defined. It is shown that the functional forms of the notch sensitivity factors proposed by Neuber and Peterson cannot be validated but a revised form can be. Calibration and validation are based on published records of fatigue tests performed on notch-free and notched test coupons fabricated from aluminum alloy and alloy steel sheets.
Zitieren
APA
Szabó, B., Actis, R., & Rusk, D. (2019). Validation of Notch Sensitivity Factors. Journal of Verification, Validation and Uncertainty Quantification, 4(1). https://doi.org/10.1115/1.4044236
Vancouver
Szabó B, Actis R, Rusk D. Validation of Notch Sensitivity Factors. Journal of Verification, Validation and Uncertainty Quantification. 2019;4(1). doi:10.1115/1.4044236
BibTeX
@article{Szab2019,
author = {Szabó, Barna and Actis, Ricardo and Rusk, David},
title = {Validation of Notch Sensitivity Factors},
journal = {Journal of Verification, Validation and Uncertainty Quantification},