EUVIMEDEUVIMED entdecken
Open Access

The Role of Simulation in the Design of a Semi-Enclosed Tubular Embolus Retrieval

Xuelian Gu, Yongxiang Qi, Arthur Erdman, Zhonghua Li

Journal of Medical Devices · 01.06.2017 · 11 (2)

DOI: 10.1115/1.4036286 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Devices, online erschienen am 03.05.2017. Verfasst von Xuelian Gu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China e-mail…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A numerical analysis of a semi-enclosed tubular mechanical embolus retrieval device (MERD) for the treatment of acute ischemic stroke (AIS) is presented. In this research, the finite element analysis (FEA) methodology is used to evaluate mechanical performance and provide suggestions for optimizing the geometric design. A MERD fabricated from nickel–titanium alloy (Nitinol) tubing is simulated and analyzed under complex in vivo loading conditions involving shape-setting, crimping, deployment, and embolus retrieval. As a result, the peak strain of the shape-setting procedure is proved to be safe for the device pattern. However, the MERD shows poor mechanical behavior after crimping into a catheter, because the peak crimping strain obtains a value of 12.1%. The delivery and deployment step demonstrates that the artery wall has little risk of serious injuries or rupture. In addition, the process of simulation of embolus retrieval and device system migration inside the cerebral artery lumen provides useful information during the design process.

Schlagwörter

Stichwörter der Autor:innen

Nitinolacute ischemic strokebiomechanicsembolus retrievalfinite element analysis

Autor:innen und Institutionen

  • Shanghai Institute for Minimally Invasive Therapy, University of Shanghai for Science and Technology, 516 Jungong Road, Shanghai 200093, China e-mail: xuelianabowen@gmail.com.
  • MicroPort Endovascular (Shanghai) Co., Ltd., 3399 Kangxin Road, Shanghai 201318, China.
  • Department of Mechanical Engineering, University of Minnesota, 111 Church Street SE #1100, Minneapolis, MN 55455 e-mail: agerdman@umn.edu.

Förderung

  • NIBIB NIH HHS

Zitieren

APA

Gu, X., Qi, Y., Erdman, A., & Li, Z. (2017). The Role of Simulation in the Design of a Semi-Enclosed Tubular Embolus Retrieval. Journal of Medical Devices, 11(2). https://doi.org/10.1115/1.4036286

Vancouver

Gu X, Qi Y, Erdman A, Li Z. The Role of Simulation in the Design of a Semi-Enclosed Tubular Embolus Retrieval. Journal of Medical Devices. 2017;11(2). doi:10.1115/1.4036286

BibTeX
@article{Gu2017,
  author = {Gu, Xuelian and Qi, Yongxiang and Erdman, Arthur and Li, Zhonghua},
  title = {The Role of Simulation in the Design of a Semi-Enclosed Tubular Embolus Retrieval},
  journal = {Journal of Medical Devices},
  year = {2017},
  volume = {11},
  number = {2},
  doi = {10.1115/1.4036286}
}
Kostenlos starten →