The Efficiencies of Internal Reforming Molten Carbonate Fuel Cell Fueled by Natural Gas and Synthetic Natural Gas From Coal

Hai-Kyung Seo, Won-shik Park, Hee Chun Lim

Journal of Electrochemical Energy Conversion and Storage · 2016

DOI: 10.1115/1.4033255 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electrochemical Energy Conversion and Storage, 2016. Verfasst von Hai-Kyung Seo und 2 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

When synthetic natural gas (SNG) is produced from coal and used as a fuel in the internal reforming molten carbonate fuel cell (ir-MCFC), electric efficiency can be no greater than 31%. This is because there are several exothermic reactions in the processes of converting coal to SNG, so that a maximum 64% of coal's energy is converted into SNG energy. This results in a lower efficiency than when the ir-MCFC with the electric efficiency of 48% is fueled by natural gas (NG). To increase electric efficiency with SNG, it is necessary to recover the exothermic heat generated from the processes of converting coal to SNG as steam, which can then be used in a steam turbine. When steam produced in the gasification, water gas shift (WGS), and methanation processes is used in a steam turbine, the gross electric efficiency will become 41%. If the steam and auxiliary power for CO2 capture process is consumed more, the net efficiency will be 27%. Use of additional steam from the exhausted gas of fuel cell can increase the total net efficiency to 49%.

Zitieren

APA

Seo, H., Park, W., & Lim, H. C. (2016). The Efficiencies of Internal Reforming Molten Carbonate Fuel Cell Fueled by Natural Gas and Synthetic Natural Gas From Coal. Journal of Electrochemical Energy Conversion and Storage. https://doi.org/10.1115/1.4033255

Vancouver

Seo H, Park W, Lim HC. The Efficiencies of Internal Reforming Molten Carbonate Fuel Cell Fueled by Natural Gas and Synthetic Natural Gas From Coal. Journal of Electrochemical Energy Conversion and Storage. 2016. doi:10.1115/1.4033255

BibTeX
@article{Seo2016,
  author = {Seo, Hai-Kyung and Park, Won-shik and Lim, Hee Chun},
  title = {The Efficiencies of Internal Reforming Molten Carbonate Fuel Cell Fueled by Natural Gas and Synthetic Natural Gas From Coal},
  journal = {Journal of Electrochemical Energy Conversion and Storage},
  year = {2016},
  doi = {10.1115/1.4033255}
}
Kostenlos starten →