Non‐invasive estimation of muscle fibre size from high‐density electromyography
The Journal of Physiology · 2023
DOI: 10.1113/jp284170 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Physiology, 2023. Verfasst von Andrea Casolo und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Sciences, University of Padova, Padua, Italy. Hauptthemen laut MEDLINE: Neural Conduction, Muscle Fibers, Skeletal. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Because of the biophysical relation between muscle fibre diameter and the propagation velocity of action potentials along the muscle fibres, motor unit conduction velocity could be a non‐invasive index of muscle fibre size in humans. However, the relation between motor unit conduction velocity and fibre size has been only assessed indirectly in animal models and in human patients with invasive intramuscular EMG recordings, or it has been mathematically derived from computer simulations. By combining advanced non‐invasive techniques to record motor unit activity in vivo , i.e. high‐density surface EMG, with the gold standard technique for muscle tissue sampling, i.e. muscle biopsy, here we investigated the relation between the conduction velocity of populations of motor units identified from the biceps brachii muscle, and muscle fibre diameter. We demonstrate the possibility of predicting muscle fibre diameter ( R 2 = 0.66) and cross‐sectional area ( R 2 = 0.65) from conduction velocity estimates with low systematic bias (∼2% and ∼4% respectively) and a relatively low margin of individual error (∼8% and ∼16%, respectively). The proposed neuromuscular interface opens new perspectives in the use of high‐density EMG as a non‐invasive tool to estimate muscle fibre size without the need of surgical biopsy sampling. The non‐invasive nature of high‐density surface EMG for the assessment of muscle fibre size may be useful in studies monitoring child development, ageing, space and exercise physiology, although the applicability and validity of the proposed methodology need to be more directly assessed in these specific populations by future studies. image Key points Because of the biophysical relation between muscle fibre size and the propagation velocity of action potentials along the sarcolemma, motor unit conduction velocity could represent a potential non‐invasive candidate for estimating muscle fibre size in vivo . This relation has been previously assessed in animal models and humans with invasive techniques, or it has been mathematically derived from simulations. By combining high‐density surface EMG with muscle biopsy, here we explored the relation between the conduction velocity of populations of motor units and muscle fibre size in healthy individuals. Our results confirmed that motor unit conduction velocity can be considered as a novel biomarker of fibre size, which can be adopted to predict muscle fibre diameter and cross‐sectional area with low systematic bias and margin of individual error. The proposed neuromuscular interface opens new perspectives in the use of high‐density EMG as a non‐invasive tool to estimate muscle fibre size without the need of surgical biopsy sampling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Sciences, University of Padova, Padua, Italy.
- Faculty of Sport and Health Science, Ritsumeikan University, Kusatsu, Shiga, Japan.
- School of Sport, Exercise & Health Sciences, Loughborough University, Loughborough, UK.
- Versus Arthritis Centre for Sport, Exercise and Osteoarthritis Research, Loughborough University, Leicestershire, UK.
- Department of Physical Therapy and Rehabilitation Science, University of Maryland, Baltimore, MD, USA.
- Department of Movement, Human and Health Sciences, University of Rome 'Foro Italico', Rome, Italy.
ORCID-Profile: Andrea Casolo, Sumiaki Maeo, Thomas G Balshaw, Marcel B Lanza, Stefano Nuccio, Tatiana Moro, Antonio Paoli, Francesco Felici, Nicola Maffulli, Bjoern Eskofier, Thomas M Kinfe, Dario Farina, Alessandro Del Vecchio
Zitieren
APA
Casolo, A., Maeo, S., Balshaw, T. G., Lanza, M. B., Martin, N. R. W., Nuccio, S., Moro, T., Paoli, A., Felici, F., Maffulli, N., Eskofier, B., Kinfe, T. M., Folland, J. P., Farina, D., & Vecchio, A. D. (2023). Non‐invasive estimation of muscle fibre size from high‐density electromyography. The Journal of Physiology. https://doi.org/10.1113/jp284170
Vancouver
Casolo A, Maeo S, Balshaw TG, Lanza MB, Martin NRW, Nuccio S, et al. Non‐invasive estimation of muscle fibre size from high‐density electromyography. The Journal of Physiology. 2023. doi:10.1113/jp284170
BibTeX
@article{Casolo2023,
author = {Casolo, Andrea and Maeo, Sumiaki and Balshaw, Thomas G and Lanza, Marcel B and Martin, Neil R W and Nuccio, Stefano and Moro, Tatiana and Paoli, Antonio and Felici, Francesco and Maffulli, Nicola and Eskofier, Bjoern and Kinfe, Thomas M and Folland, Jonathan P and Farina, Dario and Vecchio, Alessandro Del},
title = {Non‐invasive estimation of muscle fibre size from high‐density electromyography},
journal = {The Journal of Physiology},
year = {2023},
doi = {10.1113/jp284170}
}
EUVIMED