Combined multi‐metric assessment of diaphragm contractile function in healthy humans: Feasibility, validity and reliability
Experimental Physiology · 2026
DOI: 10.1113/ep093294 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Physiology, 2026. Verfasst von Camilla R Illidi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport, Health and Exercise Sciences, College of Health, Medicine and Life Sciences, Brunel University of London, Uxbridge, UK. Hauptthemen laut MEDLINE: Diaphragm, Muscle Contraction. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The combined use of subcostal ultrasonography and respiratory manometry represents a novel, integrative method for quantifying diaphragm contractile function (force, velocity and power). We evaluated the technical feasibility, construct validity and within‐day test–retest reliability of this method during non‐volitional, volitional and reflexive respiratory perturbations in healthy adults. Two independent cohorts were studied. In Experiment 1 ( n = 10), diaphragm excursion (subcostal ultrasonography) and transdiaphragmatic pressure ( P di , manometry) were measured during unilateral magnetic phrenic nerve stimulation (non‐potentiated and potentiated twitches, paired stimuli at 10–100 Hz) and maximal sniffs. In Experiment 2 ( n = 8), the same measurements were obtained during progressive CO 2 rebreathing. All protocols were repeated after 20 min of rest. Diaphragm velocity and power were calculated as excursion/time and P di × velocity, respectively. Ultrasound analysis was successful in >95% of cases. Potentiated twitches elicited greater P di , excursion and power than non‐potentiated twitches, with responses increasing at higher stimulation frequencies. Reliability improved with potentiation and high‐frequency stimulation and was moderate to excellent for peak responses during sniffs and CO 2 rebreathing (ICC 3, k = 0.70–0.94) but poor for slope‐based measures (ICC 3, k ≤ 0.20). During CO 2 rebreathing, excursion and velocity correlated strongly with inspiratory tidal volume ( r = 0.83, P < 0.001) and mean inspiratory flow ( r = 0.69, P < 0.001), respectively. These findings demonstrate that subcostal ultrasonography combined with manometry is a feasible, valid and reliable method for assessing diaphragm contractile function across non‐volitional, volitional and reflexive perturbations. With further refinement, this integrated method has translational potential for mechanistic research and clinical application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Sport, Health and Exercise Sciences, College of Health, Medicine and Life Sciences, Brunel University of London, Uxbridge, UK.
ORCID-Profile: Lee M Romer
Zitieren
APA
Illidi, C. R., & Romer, L. M. (2026). Combined multi‐metric assessment of diaphragm contractile function in healthy humans: Feasibility, validity and reliability. Experimental Physiology. https://doi.org/10.1113/ep093294
Vancouver
Illidi CR, Romer LM. Combined multi‐metric assessment of diaphragm contractile function in healthy humans: Feasibility, validity and reliability. Experimental Physiology. 2026. doi:10.1113/ep093294
BibTeX
@article{Illidi2026,
author = {Illidi, Camilla R and Romer, Lee M},
title = {Combined multi‐metric assessment of diaphragm contractile function in healthy humans: Feasibility, validity and reliability},
journal = {Experimental Physiology},
year = {2026},
doi = {10.1113/ep093294}
}
EUVIMED