CARE‐ing for concussions: Development of the Calgary Adapted aRm Ergometer (CARE) exertion test: A physiological alternative to the Calgary Concussion Cycle Test
Experimental Physiology · 2026-11 · 111 (11) · 5166-5184
DOI: 10.1113/ep093263 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Physiology, online erschienen am 19.03.2026. Verfasst von Jonathan D Smirl und 12 weiteren Autor:innen. Beteiligte Einrichtung: Cerebrovascular Concussion Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada. Hauptthemen laut MEDLINE: Exercise Test, Brain Concussion, Arm, Physical Exertion. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council, University of Calgary, Foundation Brain Canada (Brain Canada).
Abstract (Originalsprache)
Aerobic exercise testing helps facilitate recovery post‐concussion. Current protocols (Calgary Concussion Cycling Test: CCCT) are inaccessible for athletes with lower‐body impairments (i.e. Para athletes). This study compared physiological parameters for a novel arm crank test, the Calgary Adapted aRm Ergometer (CARE) test, with the CCCT. Twenty non‐disabled adults (10F:10M, aged 18–51) completed CCCT and CARE to volitional fatigue. Middle cerebral artery velocity (MCAv), heart rate (HR), mean arterial pressure (MAP) and end‐tidal carbon dioxide () were continuously measured throughout exertion. Bland–Altman with 95% limits‐of‐agreement (LoA), mean differences with effect size measurement and intraclass correlation (ICC) compared CCCT to CARE at 25%, 50%, 75% and 100% of test exertion levels. Test duration was comparable between protocols ( P = 0.86). HR mean differences between CCCT and CARE ranged from 2 bpm ( P = 0.45) at 25% to 8 bpm ( P < 0.05) at 100% effort level (negligible‐to‐medium effect sizes). MCAv mean differences increased from 1.5 cm/s at 25% ( P = 0.45) to 5.4 cm/s at 100% effort ( P < 0.05) (small effect sizes). MAP remained stable: 4.1 mmHg at 25% ( P = 0.11) and 4.8 mmHg at 100% effort ( P = 0.076) (small effect sizes). mean differences increased until 75% effort level (2.4 to 4.9 Torr, P < 0.05, medium‐to‐large effect size). ICC was good‐to‐moderate across all measurements with 95% LoA widening with increased test intensity. The CARE test represents a promising alternative to traditional lower body exercise tests, demonstrating robust physiological responses and moderate comparability with the CCCT. CARE vs. CCCT differences likely resulted from different total muscle mass engagement between the upper and lower body.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cerebrovascular Concussion Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.
- Sport Injury Prevention Research Centre, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada.
- Hotchkiss Brain Institute, University of Calgary, Calgary, Alberta, Canada.
- Integrated Concussion Research Program, University of Calgary, Calgary, Alberta, Canada.
- Alberta Children's Hospital Research Institute, University of Calgary, Calgary, Alberta, Canada.
ORCID-Profile: Joshua J Burkart, Matthew G Neill, Joel S Burma
Förderung
- Natural Sciences and Engineering Research Council
- University of Calgary
- Foundation Brain Canada (Brain Canada)
- Brain Changes Initiative
- Branch Out Neurological Foundation
- Hotchkiss Brain Institute, University of Calgary
Zitieren
APA
Smirl, J. D., Burkart, J. J., Neill, M. G., Galarneau, J. M., Fletcher, E. K. S., Burma, J. S., Johnson, N. E., Leddy, J. J., Haider, M. N., Adams, W. M., Blauwet, C., Debert, C. T., & Emery, C. A. (2026). CARE‐ing for concussions: Development of the Calgary Adapted aRm Ergometer (CARE) exertion test: A physiological alternative to the Calgary Concussion Cycle Test. Experimental Physiology, 111(11), 5166-5184. https://doi.org/10.1113/ep093263
Vancouver
Smirl JD, Burkart JJ, Neill MG, Galarneau JM, Fletcher EKS, Burma JS, et al. CARE‐ing for concussions: Development of the Calgary Adapted aRm Ergometer (CARE) exertion test: A physiological alternative to the Calgary Concussion Cycle Test. Experimental Physiology. 2026;111(11):5166-5184. doi:10.1113/ep093263
BibTeX
@article{Smirl2026,
author = {Smirl, Jonathan D and Burkart, Joshua J and Neill, Matthew G and Galarneau, Jean-Michel and Fletcher, Elizabeth K S and Burma, Joel S and Johnson, Nathan E and Leddy, John J and Haider, Mohammad N and Adams, William M and Blauwet, Cheri and Debert, Chantel T and Emery, Carolyn A},
title = {CARE‐ing for concussions: Development of the Calgary Adapted aRm Ergometer (CARE) exertion test: A physiological alternative to the Calgary Concussion Cycle Test},
journal = {Experimental Physiology},
year = {2026},
volume = {111},
number = {11},
pages = {5166--5184},
doi = {10.1113/ep093263}
}
EUVIMED