Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake
Experimental Physiology · 2023
DOI: 10.1113/ep090878 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Physiology, 2023. Verfasst von Samuel Meyler und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Life and Medical Sciences, University of Hertfordshire, Hatfield, UK. Hauptthemen laut MEDLINE: Exercise Tolerance, Oxygen Consumption. Die Arbeit wurde bisher 67-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The objective of this study was to determine whether the variability in exercise tolerance and physiological responses is lower when exercise is prescribed relative to physiological thresholds (THR) compared to traditional intensity anchors (TRAD). Ten individuals completed a series of maximal exercise tests and a series of moderate (MOD), heavy (HVY) and severe intensity (HIIT) exercise bouts prescribed using THR intensity anchors (critical power and gas exchange threshold) and TRAD intensity anchors (maximum oxygen uptake; ). There were no differences in exercise tolerance or acute response variability between MOD THR and MOD TRAD . All individuals completed HVY THR but only 30% completed HVY TRAD . Compared to HVY THR , where work rates were all below critical power, work rates in HVY TRAD exceeded critical power in 70% of individuals. There was, however, no difference in acute response variability between HVY THR and HVY TRAD . All individuals completed HIIT THR but only 20% completed HIIT TRAD . The variability in peak ( F = 0.274) and average ( F = 0.318) blood lactate responses was lower in HIIT THR compared to HIIT TRAD . The variability in W′ depletion (the finite work capacity above critical power) after the final interval bout was lower in HIIT THR compared to HIIT TRAD ( F = 0.305). Using physiological thresholds to prescribe exercise intensity reduced the heterogeneity in exercise tolerance and physiological responses to exercise spanning the boundary between the heavy and severe intensity domains. To increase the precision of exercise intensity prescription, it is recommended that, where possible, physiological thresholds are used in place of .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Life and Medical Sciences, University of Hertfordshire, Hatfield, UK.
ORCID-Profile: Samuel Meyler, Lindsay Bottoms, Daniel Muniz-Pumares
Zitieren
APA
Meyler, S., Bottoms, L., Wellsted, D., & Muniz-Pumares, D. (2023). Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake. Experimental Physiology. https://doi.org/10.1113/ep090878
Vancouver
Meyler S, Bottoms L, Wellsted D, Muniz-Pumares D. Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake. Experimental Physiology. 2023. doi:10.1113/ep090878
BibTeX
@article{Meyler2023,
author = {Meyler, Samuel and Bottoms, Lindsay and Wellsted, David and Muniz-Pumares, Daniel},
title = {Variability in exercise tolerance and physiological responses to exercise prescribed relative to physiological thresholds and to maximum oxygen uptake},
journal = {Experimental Physiology},
year = {2023},
doi = {10.1113/ep090878}
}
EUVIMED