EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

A Dual-Functional Color-Shiftable Ion Imprinted Polymer for Visual Detection and Online Preconcentration of Trace Cu2+

Dita Arifa Nurani, Untung Triadhi, Dian Ayu Setyorini, Muhammad Bachri Amran

Malaysian Journal of Fundamental and Applied Sciences · 30.10.2026 · 22 (5) · 974-990

DOI: 10.11113/mjfas.v22n5.5642 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Malaysian Journal of Fundamental and Applied Sciences, online erschienen am 30.10.2026. Verfasst von Dita Arifa Nurani und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A dual-functional Cu-Ion Imprinted Polymer (Cu-IIP) was prepared using a facile imprinting method as a color-responsive adsorbent for simultaneous visual detection and selective online preconcentration of trace Cu2+ ions. Cu-IIP was obtained by bulk polymerization using the chromophore ligand 4-pyridylazo resorcinol (PAR), the functional monomer 4-vinyl pyridine, the crosslinker ethylene glycol dimethacrylate (EGDMA), the porogen methanol, and the initiator benzoyl peroxide (BPO) under mild condition (T 65 oC ) for 2h. The synthesized imprinted polymers exhibited a maximum adsorption capacity of 67.32 mg. g-1 for Cu2+ ions. Adsorption equilibrium followed Langmuir isotherm model (R2 0.9883), indicating homogeneous binding sites. The pseudo-second-order kinetic model (R2 0.9999) most accurately represents kinetic data, indicating significant chemical interactions between the metal ions and the sorbent. The thermodynamic parameters confirmed that the adsorption process is both spontaneous and exothermic (DG< 0). The Cu-IIP was integrated into an online Flow Injection Analysis (FIA) coupled with flame atomic absorption spectrometry (FIA-FAAS). The method showed a good linearity from 100-1000 mg. L-1 with R2 0.9919, a detection limit (LoD) of 3.07 mg. L-1, a LoQ of 9.03 mg. L-1, a preconcentration factor of 2.2, and a good precision 3.53%. Application of Cu-IIP-FIA-FAAS system to a water sample demonstrated high accuracy, with recovery values 102.9-105.5%. In addition, the incorporation of PAR demonstrated a distinct concentration-dependent color change, highlighting its dual functionality as both a selective

Zitieren

APA

Nurani, D. A., Triadhi, U., Setyorini, D. A., & Amran, M. B. (2026). A Dual-Functional Color-Shiftable Ion Imprinted Polymer for Visual Detection and Online Preconcentration of Trace Cu2+. Malaysian Journal of Fundamental and Applied Sciences, 22(5), 974-990. https://doi.org/10.11113/mjfas.v22n5.5642

Vancouver

Nurani DA, Triadhi U, Setyorini DA, Amran MB. A Dual-Functional Color-Shiftable Ion Imprinted Polymer for Visual Detection and Online Preconcentration of Trace Cu2+. Malaysian Journal of Fundamental and Applied Sciences. 2026;22(5):974-990. doi:10.11113/mjfas.v22n5.5642

BibTeX
@article{Nurani2026,
  author = {Nurani, Dita Arifa and Triadhi, Untung and Setyorini, Dian Ayu and Amran, Muhammad Bachri},
  title = {A Dual-Functional Color-Shiftable Ion Imprinted Polymer for Visual Detection and Online Preconcentration of Trace Cu2+},
  journal = {Malaysian Journal of Fundamental and Applied Sciences},
  year = {2026},
  volume = {22},
  number = {5},
  pages = {974--990},
  doi = {10.11113/mjfas.v22n5.5642}
}
Kostenlos starten →