ECG Features in Orthotopic Cardiac Xenotransplantation: Comparisons With Published Literature
Xenotransplantation · 2024
DOI: 10.1111/xen.70005 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Xenotransplantation, 2024. Verfasst von Chace B Mitchell und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiac Surgery, Department of Surgery, Children's Hospital Los Angeles, Keck School of Medicine, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Transplantation, Heterologous, Heart Transplantation, Electrocardiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NHLBI NIH HHS, Eledon pharmaceuticals.
Abstract (Originalsprache)
Introduction
Although there is a plethora of literature on electrocardiographic changes following cardiac allotransplantation, there is little in the field of cardiac xenotransplantation. The only published literature to date is that of the first pig‐to‐human cardiac xenotransplantation. Here we take a close look at the electrocardiographic parameters in four non‐human primate recipients of orthotopic cardiac xenotransplantation to develop baseline metrics for comparison.
Methods
Orthotopic cardiac xenotransplantion was carried out in four non‐human primate recipients. Electrocardiographic parameters were followed at various intervals using an internal hemodynamic monitoring system (DSI) as well as a standard 12‐lead electrocardiogram (ECG). ECG intervals were then compared to published literature on porcine ECG intervals and pig‐to‐human cardiac xenotransplantation.
Results
There were no significant differences observed between timepoints for HR, PR, QRS, QT, or QTc after cardiac xenotransplantation for each animal subject. ECG parameters were statistically similar to those of in situ mini‐pig hearts in the literature. ECG parameters from the DSI on average were shorter than those from a traditional ECG, however, DSI parameters were consistent over time.
Conclusion
These results demonstrate the possibility of conduction health for genetically engineered porcine donor hearts following cardiac xenotransplantation. Ongoing work to compare the results of an ECG in a porcine donor heart before and after implantation into a NHP is necessary to better characterize variables that may be at play in the function of the conduction system.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiac Surgery, Department of Surgery, Children's Hospital Los Angeles, Keck School of Medicine, Los Angeles, California, USA.
- Department of Comparative Medicine, Michale E. Keeling Center for Comparative Medicine, MD Anderson Cancer Center, Bastrop, Texas, USA.
- Division of Cardiology, Department of Pediatrics, Children's Hospital Los Angeles, Keck School of Medicine, Los Angeles, California, USA.
ORCID-Profile: Chace B Mitchell, Joe Simmons
Förderung
- NIH HHS
- NHLBI NIH HHS
- Eledon pharmaceuticals
- eGenesis Biotechnology
- National Heart, Lung, and Blood Institute
- National Institutes of Health
Zitieren
APA
Mitchell, C. B., Simmons, J., Neal, S. J., Cleveland, D. C., Bar-Cohen, Y., & Cleveland, J. D. (2024). ECG Features in Orthotopic Cardiac Xenotransplantation: Comparisons With Published Literature. Xenotransplantation. https://doi.org/10.1111/xen.70005
Vancouver
Mitchell CB, Simmons J, Neal SJ, Cleveland DC, Bar-Cohen Y, Cleveland JD. ECG Features in Orthotopic Cardiac Xenotransplantation: Comparisons With Published Literature. Xenotransplantation. 2024. doi:10.1111/xen.70005
BibTeX
@article{Mitchell2024,
author = {Mitchell, Chace B and Simmons, Joe and Neal, Sarah J and Cleveland, David C and Bar-Cohen, Yaniv and Cleveland, John D},
title = {ECG Features in Orthotopic Cardiac Xenotransplantation: Comparisons With Published Literature},
journal = {Xenotransplantation},
year = {2024},
doi = {10.1111/xen.70005}
}
EUVIMED