EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Intensive Surveillance of Porcine‐Rhesus Kidney Xenotransplant Using Different Ultrasound Techniques

Ruochen Qi iD, Shuaijun Ma, Shichao Han, Guohui Wang, Xiaoyan Zhang, Kepu Liu, Yuanyuan Sun, Xue Gong, Ming Yu, Xuan Zhang iD, Xiaojian Yang, Kefeng Dou iD und 1 weitere

Xenotransplantation · 2024

DOI: 10.1111/xen.12873 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Xenotransplantation, 2024. Verfasst von Ruochen Qi und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Xi-Jing Hospital, Fourth Military Medical University, Xi'an, China. Hauptthemen laut MEDLINE: Transplantation, Heterologous, Kidney Transplantation, Graft Rejection, Kidney. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Significant progress has been made in kidney xenotransplantation in the past few years, and this field is accelerating towards clinical translation. Therefore, surveillance of the xenograft with appropriate tools is of great importance. Ultrasonography has been widely used in kidney allotransplantation and served as an economical and non‐invasive method to monitor the allograft. However, questions remain whether the ultrasonographic criteria established for human kidney allograft could also be applied in xenotransplantation.

Methods

In the current study, we established a porcine‐rhesus life sustaining kidney xenotransplantation model. The xenograft underwent intensive surveillance using gray‐scale, colorful Doppler ultrasound as well as 2D shear wave elastography. The kidney growth, blood perfusion, and cortical stiffness were measured twice a day. These parameters were compared with the clinical data including urine output, chemistry, and pathological findings.

Results

The observation continued for 16 days after transplantation. Decline of urine output and elevated serum creatinine were observed on POD9 and biopsy proven antibody‐mediated rejection was seen on the same day. The xenograft underwent substantial growth, with the long axis length increased by 32% and the volume increased by threefold at the end of observation. The resistive index of the xenograft arteries elevated in response to rejection, together with impaired cortical perfusion, while the peak systolic velocity (PSV) was not compromised. The cortical stiffness also increased along with rejection.

Conclusion

In summary, the ultrasound findings of kidney xenograft shared similarities with those in allograft but possessed some unique features. A modified criteria needs to be established for further application of ultrasound in kidney xenotransplantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transplantation, HeterologousKidney TransplantationGraft RejectionKidneyHeterograftsMacaca mulattaAnimalsSwineHumansUltrasonography

Stichwörter der Autor:innen

color Doppler ultrasoundgene‐edited porcinekidney transplantationshear wave elastographyxenotransplantation

Autor:innen und Institutionen

  • Department of Urology, Xi-Jing Hospital, Fourth Military Medical University, Xi'an, China.
  • Department of Ultrasound, Xi-Jing Hospital, Fourth Military Medical University, Xi'an, China.
  • Department of Hepatobiliary Surgery, Xi-Jing Hospital, Fourth Military Medical University, Xi'an, China.

ORCID-Profile: Ruochen Qi, Xuan Zhang, Kefeng Dou

Zitieren

APA

Qi, R., Ma, S., Han, S., Wang, G., Zhang, X., Liu, K., Sun, Y., Gong, X., Yu, M., Zhang, X., Yang, X., Dou, K., & Qin, W. (2024). Intensive Surveillance of Porcine‐Rhesus Kidney Xenotransplant Using Different Ultrasound Techniques. Xenotransplantation. https://doi.org/10.1111/xen.12873

Vancouver

Qi R, Ma S, Han S, Wang G, Zhang X, Liu K, et al. Intensive Surveillance of Porcine‐Rhesus Kidney Xenotransplant Using Different Ultrasound Techniques. Xenotransplantation. 2024. doi:10.1111/xen.12873

BibTeX
@article{Qi2024,
  author = {Qi, Ruochen and Ma, Shuaijun and Han, Shichao and Wang, Guohui and Zhang, Xiaoyan and Liu, Kepu and Sun, Yuanyuan and Gong, Xue and Yu, Ming and Zhang, Xuan and Yang, Xiaojian and Dou, Kefeng and Qin, Weijun},
  title = {Intensive Surveillance of Porcine‐Rhesus Kidney Xenotransplant Using Different Ultrasound Techniques},
  journal = {Xenotransplantation},
  year = {2024},
  doi = {10.1111/xen.12873}
}
Kostenlos starten →