Consistent application of compression: An under‐considered variable in the prevention of venous leg ulcers
Wound Repair and Regeneration · 2023
DOI: 10.1111/wrr.13078 ↗Kurz gefasst
Fachartikel in der Zeitschrift Wound Repair and Regeneration, 2023. Verfasst von Harrison J Shawa und 2 weiteren Autor:innen. Beteiligte Einrichtung: Dermatology Division, VA Northern California Health Care System, Mather, California, USA. Hauptthemen laut MEDLINE: Varicose Ulcer, Leg Ulcer, Venous Insufficiency. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Venous leg ulcers, the most common leg ulcer, occur in patients with chronic venous insufficiency due to venous hypertension. Evidence supports the conservative treatment with lower extremity compression, ideally between 30–40 mm Hg. Pressures in this range provide enough force to partially collapse lower extremity veins without restricting arterial flow in patients without peripheral arterial disease. There are many options for applying such compression, and those who apply these devices have varying levels of training and backgrounds. In this quality improvement project, a single observer utilised a reusable pressure monitor to compare pressures applied using different devices by individuals in wound clinics with diverse training from specialties of dermatology, podiatry, and general surgery. Average compression was higher in the dermatology wound clinic ( n = 153) compared to the general surgery clinic ( n = 53) (35.7 ± 13.3 and 27.2 ± 8.0 mm Hg, respectively, p < 0.0001), and wraps applied by clinic staff ( n = 194) were nearly twice as likely as a self‐applied wrap ( n = 71) to have pressures greater than 40 mm Hg (relative risk: 2.2, 95% confidence interval: 1.136–4.423, p = 0.02). Pressures were also dependent upon the specific compression device used, with CircAid®s (35.5 mm Hg, SD: 12.0 mm Hg, n = 159) providing higher average pressures than Sigvaris Compreflex (29.5 mm Hg, SD: 7.7 mm Hg, n = 53, p = 0.009) and Sigvaris Coolflex (25.2 mm Hg, SD: 8.0 mm Hg, n = 32, p < 0.0001). These results indicate that the device‐provided pressure may be dependent on both the compression device and the background and training of the applicator. We propose that standardisation in the training of compression application and increased use of a point‐of‐care pressure monitor may improve the consistency of applied compression, thus improving adherence to treatment and outcomes in patients with chronic venous insufficiency.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Dermatology Division, VA Northern California Health Care System, Mather, California, USA.
- Department of Dermatology, University of California Davis, Sacramento, California, USA.
- Podiatry Division, VA Northern California Health Care System, Mather, California, USA.
ORCID-Profile: Harrison J Shawa, Roslyn Rivkah Isseroff
Zitieren
APA
Shawa, H. J., Dahle, S. E., & Isseroff, R. R. (2023). Consistent application of compression: An under‐considered variable in the prevention of venous leg ulcers. Wound Repair and Regeneration. https://doi.org/10.1111/wrr.13078
Vancouver
Shawa HJ, Dahle SE, Isseroff RR. Consistent application of compression: An under‐considered variable in the prevention of venous leg ulcers. Wound Repair and Regeneration. 2023. doi:10.1111/wrr.13078
BibTeX
@article{Shawa2023,
author = {Shawa, Harrison J and Dahle, Sara E and Isseroff, Roslyn Rivkah},
title = {Consistent application of compression: An under‐considered variable in the prevention of venous leg ulcers},
journal = {Wound Repair and Regeneration},
year = {2023},
doi = {10.1111/wrr.13078}
}
EUVIMED