EUVIMEDEUVIMED entdecken
Crossref

Comparative biomechanical study of a novel variable diameter circular external fixation device ( VDCF ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens

Rohit Kumar iD, T Sai Kumar iD, K S Kamalesh Kumar iD, Abhishek C Saxena iD, Aman Kumar Tiwari iD, Abhijit Pawde, Amarpal iD, Rekha Pathak iD, O R Vinodh Kumar iD

Veterinary Surgery · 16.11.2026

DOI: 10.1111/vsu.70177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, online erschienen am 16.11.2026. Verfasst von Rohit Kumar und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Surgery, Indian Veterinary Research Institute, Bareilly, India. Die Arbeit nennt 24 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the biomechanical performance of a novel variable diameter circular external fixation device (VDCF) with a conventional circular external fixator (CEF) using a standardized osteotomized buffalo tibia model under axial compression and torsional loading. Study design Experimental in vitro biomechanical comparative study. Sample population A total of 36 adult bovine tibiae obtained postmortem from buffaloes.

Methods

The tibiae were randomly allocated into three groups ( n = 12 each): VDCF, CEF, and intact bone. A standardized mid‐diaphyseal transverse osteotomy with a 20 mm gap was created to simulate an unstable fracture model. Constructs were subjected to axial compression and torsional testing to failure using displacement‐controlled protocols. Key biomechanical parameters evaluated included failure load, axial stiffness, and maximum torque derived from load–deformation curves. Statistical analysis was performed using one‐way ANOVA followed by Tukey's HSD test.

Results

Intact tibiae demonstrated significantly greater failure load and axial stiffness than both fixation constructs ( p < .05). No significant differences were detected between VDCF and CEF in failure load or axial stiffness ( p > .05). During torsional testing, maximum torque did not differ significantly between constructs ( p > .05); however, VDCF exhibited significantly greater torsional stiffness than CEF ( p < .05). Failure modes were primarily characterized by plastic deformation and wire bending in both constructs, while fixation‐bolt loosening was observed only in the CEF group.

Conclusion

The VDCF showed no significant differences compared with conventional circular external fixation in failure load, axial stiffness, maximum torque, and torsional strength, while exhibiting significantly greater torsional stiffness under the experimental conditions. Clinical significance/impact The VDCF represents a potential alternative fixation configuration with practical advantages in construct adaptability and cost for fracture stabilization in large animals.

Autor:innen und Institutionen

  • Division of Surgery, Indian Veterinary Research Institute, Bareilly, India.
  • Division of Epidemiology, Indian Veterinary Research Institute, Bareilly, India.

ORCID-Profile: Rohit Kumar, T Sai Kumar, K S Kamalesh Kumar, Abhishek C Saxena, Aman Kumar Tiwari, Amarpal, Rekha Pathak, O R Vinodh Kumar

Zitieren

APA

Kumar, R., Sai Kumar, T., Kamalesh Kumar, K. S., Saxena, A. C., Tiwari, A. K., Pawde, A., Amarpal, Pathak, R., & Vinodh Kumar, O. R. (2026). Comparative biomechanical study of a novel variable diameter circular external fixation device ( VDCF ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens. Veterinary Surgery. https://doi.org/10.1111/vsu.70177

Vancouver

Kumar R, Sai Kumar T, Kamalesh Kumar KS, Saxena AC, Tiwari AK, Pawde A, et al. Comparative biomechanical study of a novel variable diameter circular external fixation device ( VDCF ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens. Veterinary Surgery. 2026. doi:10.1111/vsu.70177

BibTeX
@article{Kumar2026,
  author = {Kumar, Rohit and Sai Kumar, T and Kamalesh Kumar, K S and Saxena, Abhishek C and Tiwari, Aman Kumar and Pawde, Abhijit and Amarpal and Pathak, Rekha and Vinodh Kumar, O R},
  title = {Comparative biomechanical study of a novel variable diameter circular external fixation device ( VDCF ) for stabilizing a simulated tibial fracture gap in bovine cadaver specimens},
  journal = {Veterinary Surgery},
  year = {2026},
  doi = {10.1111/vsu.70177}
}
Kostenlos starten →