3D printed patient‐specific drill guide for percutaneous pedicle screw fixation in lumbosacral vertebrae in dogs: A cadaveric study and clinical case report
Veterinary Surgery · 2026-07 · 55 (5) · 908-919
DOI: 10.1111/vsu.70115 ↗Kurz gefasst
Fallbericht in der Zeitschrift Veterinary Surgery, online erschienen am 28.04.2026. Verfasst von Kyuhyun Yeom und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Veterinary Medicine, Chungnam National University, Daejeon, Republic of Korea. Hauptthemen laut MEDLINE: Dog Diseases, Lumbar Vertebrae, Pedicle Screws, Printing, Three-Dimensional. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chungnam National University.
Abstract (Originalsprache)
Objective
To evaluate the feasibility, accuracy, and safety of percutaneous pedicle screw fixation (PPSF) in the canine lumbosacral junction using three‐dimensional (3D)‐printed patient‐specific drill guides (PSGs). Study design Cadaveric study and clinical case report. Sample population A total of 13 Beagle cadavers and one 5‐year‐old German Shepherd.
Methods
In each cadaver, one side underwent 3D‐PSG‐assisted PPSF by a novice surgeon and freehand PPSF on the contralateral side by an experienced surgeon. Outcomes included operative time (min), fluoroscopic counts, incision length (mm), vertebral canal breach (grade 0–2; grade 2 defined as relevant), and angular deviation (degrees). The clinical case underwent unilateral biportal endoscopy laminectomy and discectomy followed by 3D‐PSG‐assisted PPSF.
Results
Operative times were comparable (PSG: 22.65 ± 2.71 min; freehand: 24.82 ± 5.00 min; p = .139). Fluoroscopic acquisitions were fewer with 3D‐PSG (median 5 [5–8]) than freehand (9 [7–14]; p = .003). At L7, canal breach occurred in 1/13 (PSG) and 6/13 (freehand; p = .073); relevant were 1/1 and 4/6, respectively. At S1, breach rates did not differ: 3/13 (PSG) and 2/13 (freehand; p = 1.000); relevant were 1/3 and 1/2, respectively. Angle deviations at L7 were smaller in the 3D‐PSG (sagittal 2.58° and 5.82°, p = .018; transverse 6.4° and 12.8°, p = .036). No significant differences at S1. In the clinical case, minor breaches occurred at L7 left (medial) and S1 right (cranial). The dog exhibited normal gait at 3 months.
Conclusion
3D‐PSG‐assisted PPSF at the canine lumbosacral junction was feasible, with improved screw placement accuracy at L7 and reduced fluoroscopic exposure. Clinical significance 3D‐PSGs may standardize screw trajectory control across surgeon experience levels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- College of Veterinary Medicine, Chungnam National University, Daejeon, Republic of Korea.
ORCID-Profile: Youngjin Jeon, Haebeom Lee
Förderung
- Chungnam National University
Zitieren
APA
Yeom, K., Yoon, J., Jeon, Y., Lee, H., & Jeong, J. (2026). 3D printed patient‐specific drill guide for percutaneous pedicle screw fixation in lumbosacral vertebrae in dogs: A cadaveric study and clinical case report. Veterinary Surgery, 55(5), 908-919. https://doi.org/10.1111/vsu.70115
Vancouver
Yeom K, Yoon J, Jeon Y, Lee H, Jeong J. 3D printed patient‐specific drill guide for percutaneous pedicle screw fixation in lumbosacral vertebrae in dogs: A cadaveric study and clinical case report. Veterinary Surgery. 2026;55(5):908-919. doi:10.1111/vsu.70115
BibTeX
@article{Yeom2026,
author = {Yeom, Kyuhyun and Yoon, Jongpil and Jeon, Youngjin and Lee, Haebeom and Jeong, Jaemin},
title = {3D printed patient‐specific drill guide for percutaneous pedicle screw fixation in lumbosacral vertebrae in dogs: A cadaveric study and clinical case report},
journal = {Veterinary Surgery},
year = {2026},
volume = {55},
number = {5},
pages = {908--919},
doi = {10.1111/vsu.70115}
}
EUVIMED