Biomechanical implications of lumbar intervertebral disc fenestration in rabbits: Comparison of ex vivo and in vivo conditions as an experimental model for chrondrodystrophic dogs with type 1 intervertebral disc disease
Veterinary Surgery · 2025
DOI: 10.1111/vsu.14327 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Surgery, 2025. Verfasst von James D Crowley und 4 weiteren Autor:innen. Beteiligte Einrichtung: Surgical and Orthopedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine, University of New South Wales (UNSW) Sydn…. Hauptthemen laut MEDLINE: Lumbar Vertebrae, Intervertebral Disc Degeneration, Intervertebral Disc, Intervertebral Disc Displacement. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To compare the effect of intervertebral disc (IVD) fenestration on L3/4 range of motion (ROM) under ex vivo and in vivo conditions in a rabbit model. Study design Randomized experimental study. Animals New Zealand White rabbits (ex vivo: n = 18; in vivo: n = 12).
Methods
L3/4 motion segments were tested in lateral bending (LB), flexion‐extension (FE), and axial rotation (AR) across five groups ( n = 6 per group): control (C), ex vivo fenestration (EVF), in vivo fenestration with a 6 (IVF6) and 12 week (IVF12) timepoint, and intact/annulotomy/fenestration on the same specimen (IAF). Data are reported as ROM and neutral zone (NZ) and were compared between groups using ANOVA and t ‐tests.
Results
In IAF, fenestration increased ROM in LB, FE, and AR ( p = .030) and NZ in FE ( p = .010) compared to intact. EVF had greater ROM and NZ than C in all planes (LB, FE: p = .0010; AR: p = .030). IVF6 and IVF12 showed reduced ROM and NZ in LB and FE compared to C ( p = .020–.0010) and EVF ( p = .0010), with no difference in AR ( p = .35). IVF6 and IVF12 did not differ significantly in any plane. Right lateral bending was significantly greater than left in EVF ( p = .020), but not in IVF6 ( p = .15) or IVF12 ( p = .31).
Conclusion
Fenestration increased spinal motion ex vivo, while in vivo specimens showed reduced ROM over time, consistent with a stabilizing biological response. Clinical significance These findings provide a foundation for investigating the biological and biomechanical effects of IVD fenestration in dogs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Surgical and Orthopedic Research Laboratories (SORL), Prince of Wales Clinical School, Faculty of Medicine, University of New South Wales (UNSW) Sydney, Prince of Wales Hospital, Sydney, New South Wales, Australia.
- Queensland Veterinary Specialists, Department of Small Animal Surgery, Warana, Queensland, Australia.
ORCID-Profile: James D Crowley
Zitieren
APA
Crowley, J. D., Oliver, R. A., Wang, T., Pelletier, M. H., & Walsh, W. R. (2025). Biomechanical implications of lumbar intervertebral disc fenestration in rabbits: Comparison of ex vivo and in vivo conditions as an experimental model for chrondrodystrophic dogs with type 1 intervertebral disc disease. Veterinary Surgery. https://doi.org/10.1111/vsu.14327
Vancouver
Crowley JD, Oliver RA, Wang T, Pelletier MH, Walsh WR. Biomechanical implications of lumbar intervertebral disc fenestration in rabbits: Comparison of ex vivo and in vivo conditions as an experimental model for chrondrodystrophic dogs with type 1 intervertebral disc disease. Veterinary Surgery. 2025. doi:10.1111/vsu.14327
BibTeX
@article{Crowley2025,
author = {Crowley, James D and Oliver, Rema A and Wang, Tian and Pelletier, Matthew H and Walsh, William R},
title = {Biomechanical implications of lumbar intervertebral disc fenestration in rabbits: Comparison of ex vivo and in vivo conditions as an experimental model for chrondrodystrophic dogs with type 1 intervertebral disc disease},
journal = {Veterinary Surgery},
year = {2025},
doi = {10.1111/vsu.14327}
}
EUVIMED