EUVIMEDEUVIMED entdecken
Crossref

Evaluation of femoral isometric placement accuracy of internal brace implants and its impact on stifle stability in the management of pivot shift phenomenon following TPLO

Sebastian Wylie iD, Miguel A Solano, Alan Danielski iD

Veterinary Surgery · 2025

DOI: 10.1111/vsu.14319 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Sebastian Wylie und 2 weiteren Autor:innen. Beteiligte Einrichtung: The Ralph Veterinary Referral Center, Marlow, UK. Hauptthemen laut MEDLINE: Stifle, Osteotomy, Dog Diseases, Braces. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the impact of accurate isometric placement of internal brace implants on stifle stability following tibial plateau leveling osteotomy (TPLO) in dogs with pivot shift phenomenon and to propose a novel classification system for pivot shift grading. Study design Retrospective observational study. Animals A total of 39 dogs (46 stifles) undergoing TPLO with internal brace augmentation using SwiveLock and FASTak implants.

Methods

Medical records, intraoperative assessments, and radiographs were reviewed. Femoral implant positioning was classified as accurate or inaccurate. Pivot shift was graded pre‐, intraoperatively, and at 6‐week follow‐up using a simplified two‐grade system. Learning curves for implant accuracy were compared between implant types. Statistical analyses included χ 2 and t ‐tests, with significance set at p < .05.

Results

Accurate implant positioning was achieved in 29 of 46 stifles (63.0%). SwiveLock implants were significantly more likely to be accurately placed than FASTak anchors ( p = .016), with higher patient weight correlating with improved accuracy ( p = .012). SwiveLock implants reached an accuracy rate of 78.6% compared to 38.9% for FASTak ( p = .014). At follow‐up, mean pivot shift grade improved in 90.9% of stifles ( p < .001). Inaccurate implant positioning was significantly associated with increased internal tibial rotation ( p = .009) but not with the pivot shift grade ( p = .142).

Conclusion

Accurate isometric placement of internal brace implants is critical for optimizing stifle stability and addressing pivot shift following TPLO. Clinical significance Enhanced implant accuracy and a standardized pivot shift classification may improve surgical outcomes and guide postoperative management in dogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StifleOsteotomyDog DiseasesBracesJoint InstabilityAnterior Cruciate Ligament InjuriesAnimalsDogsRetrospective StudiesFemaleMaleTibiaFemur

Autor:innen und Institutionen

  • The Ralph Veterinary Referral Center, Marlow, UK.
  • Bristol Veterinary School, University of Bristol, Bristol, UK.

ORCID-Profile: Sebastian Wylie, Alan Danielski

Zitieren

APA

Wylie, S., Solano, M. A., & Danielski, A. (2025). Evaluation of femoral isometric placement accuracy of internal brace implants and its impact on stifle stability in the management of pivot shift phenomenon following TPLO. Veterinary Surgery. https://doi.org/10.1111/vsu.14319

Vancouver

Wylie S, Solano MA, Danielski A. Evaluation of femoral isometric placement accuracy of internal brace implants and its impact on stifle stability in the management of pivot shift phenomenon following TPLO. Veterinary Surgery. 2025. doi:10.1111/vsu.14319

BibTeX
@article{Wylie2025,
  author = {Wylie, Sebastian and Solano, Miguel A and Danielski, Alan},
  title = {Evaluation of femoral isometric placement accuracy of internal brace implants and its impact on stifle stability in the management of pivot shift phenomenon following TPLO},
  journal = {Veterinary Surgery},
  year = {2025},
  doi = {10.1111/vsu.14319}
}
Kostenlos starten →