Accuracy of a table‐bound reduction and drill guide system for minimally invasive sacroiliac screw placement in cats
Veterinary Surgery · 2026-01 · 55 (1) · 142-152
DOI: 10.1111/vsu.14251 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, online erschienen am 31.03.2025. Verfasst von Yolanda López Barroso und 3 weiteren Autor:innen. Beteiligte Einrichtung: Willows Veterinary Center and Referral Service, part of Linnaeus Veterinary Limited, Solihull, UK. Hauptthemen laut MEDLINE: Bone Screws, Sacroiliac Joint, Minimally Invasive Surgical Procedures, Fracture Fixation, Internal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To describe the equipment and accuracy of a table‐bound reduction system and three‐dimensional (3D) printed drill guide for fluoroscopically guided, minimally invasive sacroiliac luxation (SIL) reduction and stabilization by means of a single iliosacral lag screw in cats. Study design Retrospective case series. Animals A total of 17 cats (20 screws).
Methods
Medical records of a single institution were retrospectively reviewed for cats that underwent SIL reduction and stabilization as described in the above objective. Postoperative images were assessed for screw positioning, percentage of sacroiliac reduction, sacral width purchase, and craniocaudal and dorsoventral screw angulation.
Results
Sacral width purchase was 82.52% ± 10.67. Percentage of sacroiliac (SI) joint reduction was 94.25% ± 8.14. Craniocaudal screw angle was −1.22° ± 3.96. Dorsoventral screw angles was 0.7° ± 3.90. All screws were classed as being positioned within the sacral body (in).
Conclusion
Stabilization of SIL in cats by mean of a single iliosacral screw placed minimally invasively using intraoperative fluoroscopy and a table bound reduction system and 3D printed drill guide system, led to screws that were repeatably placed within the sacral body based on either computed tomography (CT) scan assessment or subjective radiographic assessment. Clinical significance The described technique and equipment allow placement of iliosacral screws in cats with repeatable accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Willows Veterinary Center and Referral Service, part of Linnaeus Veterinary Limited, Solihull, UK.
- Ferguson Veterinary Clinic, Bankhead Park, Glenrothes, UK.
Zitieren
APA
López Barroso, Y., Anesi, S., Clarke, S., & Bilmont, A. (2026). Accuracy of a table‐bound reduction and drill guide system for minimally invasive sacroiliac screw placement in cats. Veterinary Surgery, 55(1), 142-152. https://doi.org/10.1111/vsu.14251
Vancouver
López Barroso Y, Anesi S, Clarke S, Bilmont A. Accuracy of a table‐bound reduction and drill guide system for minimally invasive sacroiliac screw placement in cats. Veterinary Surgery. 2026;55(1):142-152. doi:10.1111/vsu.14251
BibTeX
@article{LpezBarroso2026,
author = {López Barroso, Yolanda and Anesi, Simone and Clarke, Stephen and Bilmont, Alexis},
title = {Accuracy of a table‐bound reduction and drill guide system for minimally invasive sacroiliac screw placement in cats},
journal = {Veterinary Surgery},
year = {2026},
volume = {55},
number = {1},
pages = {142--152},
doi = {10.1111/vsu.14251}
}