Impact of suture materials polydioxanone and poliglecaprone 25 on non‐infected clean orthopedic stifle procedure incisional dehiscence rates
Veterinary Surgery · 2025
DOI: 10.1111/vsu.14224 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Megan N Caiazzo und 3 weiteren Autor:innen. Beteiligte Einrichtung: Metropolitan Veterinary Hospital, Akron, Ohio, USA. Hauptthemen laut MEDLINE: Polydioxanone, Surgical Wound Dehiscence, Sutures, Stifle. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Objective
To compare dehiscence rates, and evaluate incisional outcome, between the use of polydioxanone (PDS) versus poliglecaprone 25 (Monocryl) suture for skin closure in dogs undergoing a variety of clean orthopedic procedures associated with the stifle. Study design Randomized, prospective, cross‐sectional design. Animals Client owned dogs with cranial cruciate disease deemed appropriate surgical candidates for tibial plateau leveling osteotomy (TPLO) or other clean orthopedic stifle procedure ( N = 232).
Methods
Dogs undergoing a TPLO, or other clean orthopedic procedure were randomly assigned to one of three groups using different closure materials. Incisional dehiscence rate in the absence of infection was analyzed against multiple variables. Infection and dehiscence were characterized based on previously published descriptions.
Results
A total of 232 dogs were analyzed with 72 in Group 1, 85 in Group 2, and 75 in Group 3. A total of 137/232 (59.05%) of dogs received postoperative antibiotics. Overall, 22/232 (9.48%) of dogs showed dehiscence without evidence of infection during the follow up period. Postoperative antibiotic use ( p = .023) and signs of infection ( p < .001) were statistically different between the healed and dehisced groups. The mean weight, body condition score, and incision length were not different between groups.
Conclusion
There is no difference in dehiscence rate in the absence of infection following a clean orthopedic procedure when comparing skin closure with PDS versus Monocryl. Clinical significance Either PDS or Monocryl may be used for skin closure following a clean orthopedic procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Metropolitan Veterinary Hospital, Akron, Ohio, USA.
ORCID-Profile: Brittany L Cortina, Alex Terreros
Zitieren
APA
Caiazzo, M. N., Cortina, B. L., Terreros, A., & Daye, R. M. (2025). Impact of suture materials polydioxanone and poliglecaprone 25 on non‐infected clean orthopedic stifle procedure incisional dehiscence rates. Veterinary Surgery. https://doi.org/10.1111/vsu.14224
Vancouver
Caiazzo MN, Cortina BL, Terreros A, Daye RM. Impact of suture materials polydioxanone and poliglecaprone 25 on non‐infected clean orthopedic stifle procedure incisional dehiscence rates. Veterinary Surgery. 2025. doi:10.1111/vsu.14224
BibTeX
@article{Caiazzo2025,
author = {Caiazzo, Megan N and Cortina, Brittany L and Terreros, Alex and Daye, R Mark},
title = {Impact of suture materials polydioxanone and poliglecaprone 25 on non‐infected clean orthopedic stifle procedure incisional dehiscence rates},
journal = {Veterinary Surgery},
year = {2025},
doi = {10.1111/vsu.14224}
}
EUVIMED