EUVIMEDEUVIMED entdecken
Crossref

Leakage pressures of partial and total lung lobectomies performed with thoracoabdominal staplers in cadaveric dogs

Yael Huerta, William T N Culp iD, Giacomo Gianotti, Nimar Gill, Darko Stefanovski, Maureen A Griffin iD

Veterinary Surgery · 2025

DOI: 10.1111/vsu.14207 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Yael Huerta und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences and Advanced Medicine, University of Pennsylvania School of Veterinary Medicine, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Pneumonectomy, Surgical Staplers, Lung, Surgical Stapling. Die Arbeit nennt 26 Literaturangaben. Gefördert von: Covidien-Medtronic.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare leakage pressures of stapled partial and total lung lobectomies using thoracoabdominal (TA) staplers in canine cadaveric specimens. Study design Ex vivo experimental study. Sample population A total of 29 lung lobes from six canine cadavers.

Methods

Lower respiratory tracts were harvested from canine cadavers >15 kg. Lung lobes were randomized to groups: total lobectomy with a TA30‐V3 (TL‐30), partial lobectomy with two TA30‐V3 cartridges in a wedge configuration (PL‐30), and partial lobectomy with a TA60‐3.5 mm (PL‐60). The leakage pressure (pressure at which air bubbles were first seen from submerged tissue) was assessed, and groups were compared.

Results

All nine PL‐30 and all nine PL‐60 sites leaked at median pressures of 10 cm H 2 O (range 10–15) and 18 cm H 2 O (range 10–20), respectively. Only 1/11 TL‐30 site leaked during testing at a pressure of 22 cm H 2 O. PL‐30 and PL‐60 sites were more likely to leak at 20 (OR: 437; 95% CI: 7.9–24 171; p = .003) and 30 (OR: 133; 95% CI: 4.8–3674.2; p = .003) cm H 2 O compared to TL‐30 sites, and the leakage pressure was greater for TL‐30 as compared to PL‐30 (marginal effect: −46.14; 95% CI: −55.9 to −36.38; p < .001) and PL‐60 (marginal effect: −41.2; 95% CI: −51.73 to −30.67; p < .001) sites. PL‐60 leakage pressures were greater than those of PL‐30 (marginal effect: 4.94; 95% CI: 1.43–8.44; p = .006).

Conclusion

In canine cadaveric lung, total lobectomies with a TA30‐V3 were less likely to leak at physiological pressures than partial lobectomies with either TA30‐V3 or TA60‐3.5 mm staplers. Clinical significance These results suggest a greater potential risk for air leakage at physiologically relevant pressures following partial as compared to total lobectomies with the TA stapling devices and techniques used commonly in veterinary surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PneumonectomySurgical StaplersLungSurgical StaplingAnimalsDogsCadaverPressure

Autor:innen und Institutionen

  • Department of Clinical Sciences and Advanced Medicine, University of Pennsylvania School of Veterinary Medicine, Philadelphia, Pennsylvania, USA.
  • Department of Surgical and Radiological Sciences, University of California-Davis School of Veterinary Medicine, Davis, California, USA.

ORCID-Profile: William T N Culp, Maureen A Griffin

Förderung

  • Covidien-Medtronic

Zitieren

APA

Huerta, Y., Culp, W. T. N., Gianotti, G., Gill, N., Stefanovski, D., & Griffin, M. A. (2025). Leakage pressures of partial and total lung lobectomies performed with thoracoabdominal staplers in cadaveric dogs. Veterinary Surgery. https://doi.org/10.1111/vsu.14207

Vancouver

Huerta Y, Culp WTN, Gianotti G, Gill N, Stefanovski D, Griffin MA. Leakage pressures of partial and total lung lobectomies performed with thoracoabdominal staplers in cadaveric dogs. Veterinary Surgery. 2025. doi:10.1111/vsu.14207

BibTeX
@article{Huerta2025,
  author = {Huerta, Yael and Culp, William T N and Gianotti, Giacomo and Gill, Nimar and Stefanovski, Darko and Griffin, Maureen A},
  title = {Leakage pressures of partial and total lung lobectomies performed with thoracoabdominal staplers in cadaveric dogs},
  journal = {Veterinary Surgery},
  year = {2025},
  doi = {10.1111/vsu.14207}
}
Kostenlos starten →