Effect of breed, obturator type and surgical experience on tenoscopic portal creation into the digital flexor tendon sheath in horses
Veterinary Surgery · 2024
DOI: 10.1111/vsu.14158 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Jonathan M White und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Veterinary Sciences, School of Veterinary Medicine, Faculty of Medical Sciences, The University of the West Indies, St. August…. Hauptthemen laut MEDLINE: Cadaver. Die Arbeit nennt 14 Literaturangaben. Gefördert von: IVC Evidensia.
Abstract (Originalsprache)
Objective
To determine the influence of breed (cob [CB] and non‐cob [NC]), obturator type and surgical experience on the number of attempts, time taken and iatrogenic damage (ID) created when entering the digital flexor tendon sheath (DFTS) tenoscopically. Study design Prospective experimental cadaveric study. Animals A total of 104 cadaver limbs.
Methods
An equal number of randomly selected CB and NC limbs were operated using a conical obturator (OB) or a switching stick (SS) by one boarded (BS) and one resident surgeon (RS). Skin measurements, number of attempts and time taken to enter the DFTS were recorded. The DFTS was endoscopically examined and then dissected to record ID and cumulative ID calculated.
Results
Mean CB skin thickness (8.4 mm) was nearly twice that of NC limbs (4.5 mm) ( p < .001). Mean DFTS entry took longer in CB limbs (133 s) compared to NC limbs (112 s) ( p = .02). BS mean entry time in CB limbs was 115 s compared to 46 s in NC limbs ( p < .001). Cumulative ID was greater in CB limbs (25 of 52 limbs with ID) compared to NC limbs (14 of 52 limbs with ID) ( p = .04). No difference was noted between obturators. Surgical experience reduced attempts and time entering the DFTS.
Conclusion
Surgeons take longer to enter DFTS in CB limbs and more cumulative ID is created, regardless of obturator type used. Clinical significance Skin thickness is a major determinant of time taken to enter the DFTS and increases the risk of ID. Awareness of the challenges in CB limbs is important.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Clinical Veterinary Sciences, School of Veterinary Medicine, Faculty of Medical Sciences, The University of the West Indies, St. Augustine, Trinidad and Tobago.
- Pool House Veterinary Clinic, Lichfield, UK.
- School of Veterinary Medicine & Science, University of Nottingham, Sutton Bonnington, UK.
ORCID-Profile: Marco Marcatili
Förderung
- IVC Evidensia
Zitieren
APA
White, J. M., Hibner-Szaltys, M., Duz, M., Withers, J. M., & Marcatili, M. (2024). Effect of breed, obturator type and surgical experience on tenoscopic portal creation into the digital flexor tendon sheath in horses. Veterinary Surgery. https://doi.org/10.1111/vsu.14158
Vancouver
White JM, Hibner-Szaltys M, Duz M, Withers JM, Marcatili M. Effect of breed, obturator type and surgical experience on tenoscopic portal creation into the digital flexor tendon sheath in horses. Veterinary Surgery. 2024. doi:10.1111/vsu.14158
BibTeX
@article{White2024,
author = {White, Jonathan M and Hibner-Szaltys, Maria and Duz, Marco and Withers, Jonathan M and Marcatili, Marco},
title = {Effect of breed, obturator type and surgical experience on tenoscopic portal creation into the digital flexor tendon sheath in horses},
journal = {Veterinary Surgery},
year = {2024},
doi = {10.1111/vsu.14158}
}
EUVIMED