Tibial fracture associated with use of Arthrex self‐tapping screws during tibial plateau leveling osteotomy in dogs and development of transcortical tibial fracture
Veterinary Surgery · 2024
DOI: 10.1111/vsu.14134 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Hailey R Gollnick und 2 weiteren Autor:innen. Beteiligte Einrichtung: Comparative Orthopaedic Research Laboratory, School of Veterinary Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Osteotomy, Tibial Fractures, Bone Screws. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
Medical records for dogs treated with tibial plateau leveling osteotomy (TPLO) using Arthrex 3.5 mm self‐tapping screws (STS) were evaluated to determine the incidence rate of transcortical tibial fractures (TCTF) and development of complications. Study design Retrospective case report. Study population A total of 78 dogs.
Methods
Dogs that underwent a TPLO performed from March 2022 to August 2023 were reviewed. Postoperative TPLO radiographs were examined for evidence of a TCTF with Arthrex 3.5 mm STS. Records were reviewed for complications up to 14 weeks after surgery.
Results
Evidence of a TCTF was found in 42% of cases (33 of 78) and 14% (36 of 250) of STS screws distal to the osteotomy. TCTFs were only identified distal to the osteotomy. Three dogs had radiographic evidence of more than one TCTF. Of the dogs with radiographic TCTF, 6% of patients (2 of 33) developed a major complication that required surgical stabilization of a tibial fracture associated with screw angulation relative to the plate.
Conclusion
Use of Arthrex 3.5 mm STS for TPLO is associated with risk of TCTF. TCTF can compromise the structural properties of the tibia and cause complete tibial fracture requiring major revision surgery. Clinical significance Development of TCTF after use of STS for TPLO has been recognized, in contrast to use of non‐self‐tapping screws, and was considered a benign complication. Our findings suggest TCTF associated with Arthrex 3.5 mm STS use in TPLO can contribute to major complications after surgery, including complete tibial fracture, particularly if screws are not placed perpendicular to the plate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Comparative Orthopaedic Research Laboratory, School of Veterinary Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Jessica McCarthy, Peter Muir
Zitieren
APA
Gollnick, H. R., McCarthy, J., & Muir, P. (2024). Tibial fracture associated with use of Arthrex self‐tapping screws during tibial plateau leveling osteotomy in dogs and development of transcortical tibial fracture. Veterinary Surgery. https://doi.org/10.1111/vsu.14134
Vancouver
Gollnick HR, McCarthy J, Muir P. Tibial fracture associated with use of Arthrex self‐tapping screws during tibial plateau leveling osteotomy in dogs and development of transcortical tibial fracture. Veterinary Surgery. 2024. doi:10.1111/vsu.14134
BibTeX
@article{Gollnick2024,
author = {Gollnick, Hailey R and McCarthy, Jessica and Muir, Peter},
title = {Tibial fracture associated with use of Arthrex self‐tapping screws during tibial plateau leveling osteotomy in dogs and development of transcortical tibial fracture},
journal = {Veterinary Surgery},
year = {2024},
doi = {10.1111/vsu.14134}
}
EUVIMED