Efficacy of virtual surgical planning and a three‐dimensional‐printed, patient‐specific reduction system to facilitate alignment of diaphyseal tibial fractures stabilized by minimally invasive plate osteosynthesis in dogs: A prospective clinical study

Logan M Scheuermann, Daniel D Lewis, Matthew D Johnson, Adam H Biedrzycki, Stanley E Kim

Veterinary Surgery · 2024

DOI: 10.1111/vsu.14118 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Logan M Scheuermann und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Sciences and the Jeff and Jo Godwin Advanced Small Animal Surgical Training Center and Canine Gait Laboratory, Co…. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Tibial Fractures, Fracture Fixation, Internal, Bone Plates. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Veterinary Orthopedic Society, College of Veterinary Medicine, University of Florida.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the efficacy of a three‐dimensional (3D)‐printed, patient‐specific reduction system for aligning diaphyseal tibial fractures stabilized using minimally invasive plate osteosynthesis (MIPO). Study design Prospective clinical trial. Sample population Fifteen client owned dogs.

Methods

Virtual 3D models of both pelvic limbs were created. Pin guides were designed to conform to the proximal and distal tibia. A reduction bridge was designed to align the pin guides based on the guides' spatial location. Guides were 3D printed, sterilized, and applied, in conjunction with transient application of a circular fixator, to facilitate indirect fracture realignment before plate application. Alignment of the stabilized tibiae was assessed using postoperative computed tomography scans.

Results

Mean duration required for virtual planning was 2.5 h and a mean of 50.7 h elapsed between presentation and surgery. Guide placement was accurate with minor median discrepancies in translation and frontal, sagittal, and axial plane positioning of 2.9 mm, 3.6°, 2.7°, and 6.8°, respectively. Application of the reduction system restored mean tibial length and frontal, sagittal, and axial alignment within 1.7 mm, 1.9°, 1.7°, and 4.5°, respectively, of the contralateral tibia.

Conclusion

Design and fabrication of a 3D‐printed, patient‐specific fracture reduction system is feasible in a relevant clinical timeline. Intraoperative pin‐guide placement was reasonably accurate with minor discrepancies compared to the virtual plan. Custom 3D‐printed reduction system application facilitated near‐anatomic or acceptable fracture reduction in all dogs. Clinical significance Virtual planning and fabrication of a 3D‐printing patient‐specific fracture reduction system is practical and facilitated acceptable, if not near‐anatomic, fracture alignment during MIPO.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalTibial FracturesFracture Fixation, InternalBone PlatesAnimalsDogsProspective StudiesMaleFemaleMinimally Invasive Surgical Procedures

Autor:innen und Institutionen

  • Department of Small Animal Clinical Sciences and the Jeff and Jo Godwin Advanced Small Animal Surgical Training Center and Canine Gait Laboratory, College of Veterinary Medicine, University of Florida, Gainesville, Flor…
  • Department of Large Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, Florida, USA.

Förderung

  • Veterinary Orthopedic Society
  • College of Veterinary Medicine, University of Florida

Zitieren

APA

Scheuermann, L. M., Lewis, D. D., Johnson, M. D., Biedrzycki, A. H., & Kim, S. E. (2024). Efficacy of virtual surgical planning and a three‐dimensional‐printed, patient‐specific reduction system to facilitate alignment of diaphyseal tibial fractures stabilized by minimally invasive plate osteosynthesis in dogs: A prospective clinical study. Veterinary Surgery. https://doi.org/10.1111/vsu.14118

Vancouver

Scheuermann LM, Lewis DD, Johnson MD, Biedrzycki AH, Kim SE. Efficacy of virtual surgical planning and a three‐dimensional‐printed, patient‐specific reduction system to facilitate alignment of diaphyseal tibial fractures stabilized by minimally invasive plate osteosynthesis in dogs: A prospective clinical study. Veterinary Surgery. 2024. doi:10.1111/vsu.14118

BibTeX
@article{Scheuermann2024,
  author = {Scheuermann, Logan M and Lewis, Daniel D and Johnson, Matthew D and Biedrzycki, Adam H and Kim, Stanley E},
  title = {Efficacy of virtual surgical planning and a three‐dimensional‐printed, patient‐specific reduction system to facilitate alignment of diaphyseal tibial fractures stabilized by minimally invasive plate osteosynthesis in dogs: A prospective clinical study},
  journal = {Veterinary Surgery},
  year = {2024},
  doi = {10.1111/vsu.14118}
}