EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Ex vivo biomechanical evaluation of an adhered fiberglass and polymethyl methacrylate sole‐hoof wall cast on stabilization of type III distal phalanx fractures under simulated physiologic midstance loads

Shane Westman, Thomas E Cullen, Thomas C Bergstrom, Lisa A Edwards, Tanya C Garcia, Susan M Stover iD

Veterinary Surgery · 2024

DOI: 10.1111/vsu.14063 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Shane Westman und 5 weiteren Autor:innen. Beteiligte Einrichtung: William R. Prichard Veterinary Medical Teaching Hospital, University of California, Davis, Davis, California, USA. Hauptthemen laut MEDLINE: Hoof and Claw, Fractures, Bone, Horse Diseases, Glass. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: UC Davis Center for Equine Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the effect of the application of a novel fiberglass‐glue cast (FGC) on the fracture gap width in experimentally created type III distal phalanx fractures in cadaveric specimens under simulated physiologic loads. Study design Ex vivo biomechanical laboratory study. Animals Nine unilateral adult equine cadaver forelimbs.

Methods

Type III distal phalanx fractures were created in forelimb specimens, which maintained distal components of the passive stay apparatus. The fracture gap was measured at 5%, 20%, 25%, 50%, 75%, and 95% of fracture length (palmar articular border to solar margin) using D65Pr‐PaDiO radiographs. The limb was axially loaded (700, 3600, 4600, and 6700 N) before, during, and after removal of a woven fiberglass cloth and polymethyl methacrylate cast that encompassed the sole and distal portion of the hoof wall (FGC). Fracture gap widths were compared among loads and treatments using a mixed model ANOVA.

Results

On average, under simulated physiological midstance loads, the fracture gap width was 0.2 mm smaller after FGC application, with the greatest decrease (0.5 mm) near the articular surface. On average, it was 0.3 mm smaller than after FGC removal. Fracture gap width was 0.1 mm greater when midstance loads transitioned from standing load to walking, trotting, and gallop loads. The fracture gap width increased by 1.3 mm with increasing distance from the articular surface.

Conclusion

The FGC reduced the fracture gap width and prevented the fracture gap widening that occurred after FGC removal. Clinical significance The findings support consideration of FGC use in the treatment of horses with type III distal phalangeal fractures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hoof and ClawFractures, BoneHorse DiseasesGlassHumansHorsesAnimalsPolymethyl MethacrylateForelimbUpper ExtremityBiomechanical Phenomena

Substanzen

fiberglassPolymethyl Methacrylate

Autor:innen und Institutionen

  • William R. Prichard Veterinary Medical Teaching Hospital, University of California, Davis, Davis, California, USA.
  • Equine Medical Center of Ocala, Ocala, Florida, USA.
  • Peterson Smith Equine Hospital, Ocala, Florida, USA.
  • Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, Davis, California, USA.

ORCID-Profile: Susan M Stover

Förderung

  • UC Davis Center for Equine Health

Zitieren

APA

Westman, S., Cullen, T. E., Bergstrom, T. C., Edwards, L. A., Garcia, T. C., & Stover, S. M. (2024). Ex vivo biomechanical evaluation of an adhered fiberglass and polymethyl methacrylate sole‐hoof wall cast on stabilization of type III distal phalanx fractures under simulated physiologic midstance loads. Veterinary Surgery. https://doi.org/10.1111/vsu.14063

Vancouver

Westman S, Cullen TE, Bergstrom TC, Edwards LA, Garcia TC, Stover SM. Ex vivo biomechanical evaluation of an adhered fiberglass and polymethyl methacrylate sole‐hoof wall cast on stabilization of type III distal phalanx fractures under simulated physiologic midstance loads. Veterinary Surgery. 2024. doi:10.1111/vsu.14063

BibTeX
@article{Westman2024,
  author = {Westman, Shane and Cullen, Thomas E and Bergstrom, Thomas C and Edwards, Lisa A and Garcia, Tanya C and Stover, Susan M},
  title = {Ex vivo biomechanical evaluation of an adhered fiberglass and polymethyl methacrylate sole‐hoof wall cast on stabilization of type III distal phalanx fractures under simulated physiologic midstance loads},
  journal = {Veterinary Surgery},
  year = {2024},
  doi = {10.1111/vsu.14063}
}
Kostenlos starten →