A mismatch of planning and achieved tibial plateau angle in cranial closing wedge surgery: An in silico and clinical evaluation of 100 cases
Veterinary Surgery · 2024
DOI: 10.1111/vsu.13998 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Charlotte Banks und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Science and Services, Queen Mother Hospital for Animals, Royal Veterinary College, London, UK. Hauptthemen laut MEDLINE: Patellar Ligament, Anterior Cruciate Ligament Injuries, Dog Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
(1) To determine whether Oxley's modified cranial closing wedge osteotomy (CCWO) results in a tibial plateau angle (TPA) of 5° in silico, (2) compare in silico to clinical postoperative TPA and (3) determine the impact of ostectomy distalization in silico. Study design Cross‐sectional retrospective radiographic in silico study. Sample population A total of 100 stifle radiographs; 90 dogs (small ≤25 kg = 84; large >25 kg = 16).
Methods
Tibial plateau angles were measured preoperatively (TPA Pre ), after in silico planning (TPA Plan ), and postoperatively (TPA Post ). Virtual ostectomies were evaluated for plate fit. Postoperative ostectomy position was measured. Virtual ostectomies were performed 5/7.5/10/15 mm from the patellar tendon insertion in 10 dogs from each preoperative TPA category (≤20°/21–25°/ 26–30°/31–35°/>35°). Comparisons for TPA Pre , TPA Post , and TPA Plan were made between small and large dogs, and the outcome to the target 5° between TPA categories and ostectomy positions.
Results
Mean ± SD TPA Pre was 28.6 ± 6.2° and higher in small than large dogs. Mean TPA Plan was 7.6 ± 2.7°. Plate fit was appropriate in all. In silico, TPAs were greater than 5° except for cases with TPA Pre > 35°. Median TPA Post was 5.5° (−4–21) and was higher in small (7°) than large (4.5°) dogs. Postoperative ostectomy position was more distal than Oxley's guidelines. When distalized >7.5 mm in silico, the magnitude of under‐correction increased.
Conclusions
Oxley's modified CCWO did not result in TPA of 5° in most cases. Ostectomy distalization exacerbated under‐correction. Clinical impact Current guidelines should be modified to achieve 5° TPA postoperatively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Clinical Science and Services, Queen Mother Hospital for Animals, Royal Veterinary College, London, UK.
ORCID-Profile: Charlotte Banks, Gareth Michael Couper Jones, Richard Lawrence Meeson
Zitieren
APA
Banks, C., Jones, G. M. C., & Meeson, R. L. (2024). A mismatch of planning and achieved tibial plateau angle in cranial closing wedge surgery: An in silico and clinical evaluation of 100 cases. Veterinary Surgery. https://doi.org/10.1111/vsu.13998
Vancouver
Banks C, Jones GMC, Meeson RL. A mismatch of planning and achieved tibial plateau angle in cranial closing wedge surgery: An in silico and clinical evaluation of 100 cases. Veterinary Surgery. 2024. doi:10.1111/vsu.13998