EUVIMEDEUVIMED entdecken
Crossref

Variables affecting surgeons’ use of, and preferences for, instrumentation in veterinary laparoscopy

Meghan R Smith, Nicole J Buote iD, Julia P Sumner, Lynetta J Freeman

Veterinary Surgery · 2024

DOI: 10.1111/vsu.13995 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Meghan R Smith und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA. Hauptthemen laut MEDLINE: Laparoscopy, Surgeons. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To investigate the impact of variables on use and preference of common laparoscopic instruments. Study design Online survey. Sample population Surgeons ( n = 140) with 3 years or more laparoscopic experience.

Methods

Electronic survey distributed via specialty group LISTSERVEs and Facebook groups. Responses collected included surgeon attributes, preferences, and surgical practice data. Statistical analysis was performed using Fishers exact, ANOVA, Tukey Kramer honestly significant difference (HSD) test, linear regression, and logistic regression.

Results

Ninety‐eight of 140 respondents answered instrument‐related questions and the completion rate of these questions was 76%: 48% of females and 49% of males responded to the survey. The median glove size of respondents was size 7 (range, 5.5 to 8.5). Closing laparoscopic Babcock forceps ( p = .018), rotating cup biopsy forceps ( p = .003), and manipulating endoscopic staplers ( p < .001) were more difficult for surgeons with smaller glove sizes. The median difficulty score for the endoscopic stapler was 4/10 and the median percentage of time this was found difficult was 25%. Reusable instruments were preferred over disposable single‐use instruments. The pistol grip was preferred for grasping and retracting (54/98, 55%) and fine dissection (46/96, 48%), while the axial grip was preferred for suturing and knot tying (61/98, 62%).

Conclusion

Surgeons with smaller glove sizes (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LaparoscopySurgeonsMaleFemaleAnimalsHumansErgonomicsSurgical InstrumentsSurveys and Questionnaires

Autor:innen und Institutionen

  • Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York, USA.
  • Small Animal Specialist Hospital, Sydney, New South Wales, Australia.
  • Emeritus Professor, Purdue University College of Veterinary Medicine, West Lafayette, Indiana, USA.

ORCID-Profile: Nicole J Buote

Zitieren

APA

Smith, M. R., Buote, N. J., Sumner, J. P., & Freeman, L. J. (2024). Variables affecting surgeons’ use of, and preferences for, instrumentation in veterinary laparoscopy. Veterinary Surgery. https://doi.org/10.1111/vsu.13995

Vancouver

Smith MR, Buote NJ, Sumner JP, Freeman LJ. Variables affecting surgeons’ use of, and preferences for, instrumentation in veterinary laparoscopy. Veterinary Surgery. 2024. doi:10.1111/vsu.13995

BibTeX
@article{Smith2024,
  author = {Smith, Meghan R and Buote, Nicole J and Sumner, Julia P and Freeman, Lynetta J},
  title = {Variables affecting surgeons’ use of, and preferences for, instrumentation in veterinary laparoscopy},
  journal = {Veterinary Surgery},
  year = {2024},
  doi = {10.1111/vsu.13995}
}
Kostenlos starten →