EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Biomechanical comparison of compact versus standard flute drill bits, and interlocking versus buttress thread self‐tapping cortical bone screws in cadaveric equine third metacarpal condyle

Jannah L Pye iD, Tanya C Garcia, Amy S Kapatkin, Monika A Samol iD, Susan Stover iD

Veterinary Surgery · 2023

DOI: 10.1111/vsu.13965 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2023. Verfasst von Jannah L Pye und 4 weiteren Autor:innen. Beteiligte Einrichtung: William R. Pritchard Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California-Davis, Davis, California, USA. Hauptthemen laut MEDLINE: Metacarpal Bones, Horse Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Dolly Green Endowment of the JD Wheat Veterinary Orthopedic Research Laboratory, Veterinary Orthopedic Society Wade O. Brinker Resident Research Award.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare (1) performance of compact versus standard flute drill bits, (2) screw insertion properties and (3) pullout variables between interlocking thread (ITS) and buttress thread (BTS) self‐tapping screws in third metacarpi. Study design In vitro experimental study. Sample population Paired third metacarpi from 11 Thoroughbreds aged 2–4 years.

Methods

Screws were inserted into the lateral condylar fossae following bone preparation using the respective drill bit for each screw type. Screw pullout was achieved using a mechanical testing system. Density and porosity of bone surrounding screw holes was measured with microcomputed tomography following each pullout test. Drilling, screw insertion and pullout variables were compared between drill bit and screw types using repeated measures ANOVA. Linear regression analyses were used to characterize relationships between bone tissue properties and drill bit and screw outcomes.

Results

Maximum torque power spectral density (PSD) was lower for compact flute drill bits. Insertion torque was 50% higher for ITS. BTS had 33% greater preyield stiffness and 7% greater mean yield force. Bone tissue properties affected measured variables similarly for both screw and drill bit types.

Conclusions

Lower torque PSD may increase durability of the compact flute drill bit. ITS had greater insertional torque, which may reflect greater bone engagement. BTS had greater resistance to axial pullout forces. Clinical significance Metacarpal bone provides a simple model for comparison of drill bit and screw designs. Use of ITS to repair equine fractures subject to predominantly tensile forces is not justified based on the results of this study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Metacarpal BonesHorse DiseasesAnimalsHorsesX-Ray MicrotomographyBiomechanical PhenomenaBone ScrewsCortical BoneTorqueCadaver

Autor:innen und Institutionen

  • William R. Pritchard Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.
  • JD Wheat Veterinary Orthopedic Research Laboratory, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.
  • Department of Surgical & Radiological Sciences, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.
  • California Animal Health and Food Safety System, San Bernadino Branch, School of Veterinary Medicine, University of California-Davis, Davis, California, USA.

ORCID-Profile: Jannah L Pye, Monika A Samol, Susan Stover

Förderung

  • Dolly Green Endowment of the JD Wheat Veterinary Orthopedic Research Laboratory
  • Veterinary Orthopedic Society Wade O. Brinker Resident Research Award

Zitieren

APA

Pye, J. L., Garcia, T. C., Kapatkin, A. S., Samol, M. A., & Stover, S. (2023). Biomechanical comparison of compact versus standard flute drill bits, and interlocking versus buttress thread self‐tapping cortical bone screws in cadaveric equine third metacarpal condyle. Veterinary Surgery. https://doi.org/10.1111/vsu.13965

Vancouver

Pye JL, Garcia TC, Kapatkin AS, Samol MA, Stover S. Biomechanical comparison of compact versus standard flute drill bits, and interlocking versus buttress thread self‐tapping cortical bone screws in cadaveric equine third metacarpal condyle. Veterinary Surgery. 2023. doi:10.1111/vsu.13965

BibTeX
@article{Pye2023,
  author = {Pye, Jannah L and Garcia, Tanya C and Kapatkin, Amy S and Samol, Monika A and Stover, Susan},
  title = {Biomechanical comparison of compact versus standard flute drill bits, and interlocking versus buttress thread self‐tapping cortical bone screws in cadaveric equine third metacarpal condyle},
  journal = {Veterinary Surgery},
  year = {2023},
  doi = {10.1111/vsu.13965}
}
Kostenlos starten →