Influence of 4 drain configurations on fluid dispersal and retrieval in an instillation model
Veterinary Surgery · 2023
DOI: 10.1111/vsu.13953 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2023. Verfasst von Miriam Bates und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA. Hauptthemen laut MEDLINE: Suction. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Objective
To describe and compare the pattern of fluid dispersal and retrieval in a novel instillation therapy system. Study design In vitro experimental study.
Methods
A 10 cm 2 square model was constructed using plastic sheeting secured to plexiglass, with a wound infusion catheter and Jackson‐Pratt (JP) active suction drain positioned in 4 configurations: parallel, perpendicular, diagonal, and opposite. Fluid was instilled using the wound infusion catheter, allowed to dwell for 10 min, and retrieved using the JP drain. Two surface area calculations were made using imaging software: coloration with diluted methylene blue (MB) on photos, and filling with diluted contrast on fluoroscopic images. Fluid retrieval was recorded. Statistical analysis was performed using a mixed‐effects linear model ( p < .05).
Results
Configuration influenced fluid dispersion within the model ( p = .0001); the diagonal configuration had the greatest surface area coverage (mean ± SD; 94.5 ± 2.4%) and the parallel configuration had the lowest surface area coverage (60.2 ± 2.9%). A dwell period increased fluid dispersal by an average of 4.0 ± 0.8% ( p < .0001). Fluid retrieval exceeded 16.7 ± 1.5 mL (83.5 ± 7.5% volume instilled) for all configurations and was 0.5 ± 0.1 mL (2.5 ± 0.5% volume instilled) greater for MB than contrast agent ( p < .0001).
Conclusion
Perpendicular or diagonal configurations and low‐viscosity fluid maximized fluid dispersion and retrieval. Clinical significance Wound instillation therapy involves delivering lavage fluid or medications to a closed wound space. This is feasible using a wound‐infusion catheter and active suction drain. Configuration should be considered to optimize fluid dispersal and retrieval when planning instillation therapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA.
- Department of Veterinary Administration, College of Veterinary Medicine, Purdue University, West Lafayette, Indiana, USA.
ORCID-Profile: Marije Risselada
Zitieren
APA
Bates, M., Risselada, M., & Moore, G. E. (2023). Influence of 4 drain configurations on fluid dispersal and retrieval in an instillation model. Veterinary Surgery. https://doi.org/10.1111/vsu.13953
Vancouver
Bates M, Risselada M, Moore GE. Influence of 4 drain configurations on fluid dispersal and retrieval in an instillation model. Veterinary Surgery. 2023. doi:10.1111/vsu.13953
BibTeX
@article{Bates2023,
author = {Bates, Miriam and Risselada, Marije and Moore, George E},
title = {Influence of 4 drain configurations on fluid dispersal and retrieval in an instillation model},
journal = {Veterinary Surgery},
year = {2023},
doi = {10.1111/vsu.13953}
}
EUVIMED