EUVIMEDEUVIMED entdecken
Crossref

Scope of Adoption of Standardized Structure Nomenclature in Veterinary Radiation Oncology

Konstantina J Giapintzaki, Del Leary, Thomas Ber-In Lee, Melanie Linn, Nicholas Rancilio iD, Imran Shah, Parminder S Basran iD

Veterinary Radiology & Ultrasound · 2026

DOI: 10.1111/vru.70168 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Radiology & Ultrasound, 2026. Verfasst von Konstantina J Giapintzaki und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, College of Veterinary Medicine, Ithaca, New York, USA. Hauptthemen laut MEDLINE: Radiation Oncology, Terminology as Topic, Veterinary Medicine. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this study is to investigate how well veterinary institutions have adopted to the structure naming conventions provided by the American Association of Physicists in Medicine (AAPM) Task Group 263 (TG‐263). The TG‐263 standard nomenclature has been suggested as a means of reducing the uncertainty in structure definitions in radiation oncology. Our interest is in understanding whether these recommendations have been adopted in the veterinary radiation oncology setting. This study includes a convenience sample survey of five veterinary institutions across the United States, each with 38–102 total structure names defined across their templates. The data were examined in two steps: an automated check that flagged forbidden characters, spaces, and exceeding length, and a manual review for abbreviations (e.g., L/R), uniqueness, and mapping to the TG‐263 structure spreadsheet and SNOMED (Systematized Nomenclature of Medicine) Veterinary Extension. Each structure was classified as compliant, having one error, multiple errors, or uniquely defined by the institution. The results were analyzed by determining the percentages of each category per institution. Our results suggest wide variability with a mean compliance of 55.2% and a standard deviation of 35.2%, which suggests no clear trend.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation OncologyTerminology as TopicVeterinary MedicineAnimalsUnited StatesSystematized Nomenclature of Medicine

Stichwörter der Autor:innen

Task Group 263 (TG‐263)radiation oncologystructure nomenclatureveterinary radiation therapy

Autor:innen und Institutionen

  • Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, College of Veterinary Medicine, Ithaca, New York, USA.
  • Department of Environmental and Radiological Health Sciences, Colorado State University, Fort Collins, Colorado, USA.
  • Department of Clinical Sciences and Advanced Medicine, University of Pennsylvania School of Veterinary Medicine (PennVet Cancer Center), Philadelphia, Pennsylvania, USA.
  • MedVet, Cincinnati, Cincinnati, Ohio, USA.
  • Veterinary Clinical Sciences, Iowa State University, Patterson Hall, Ames, Iowa, USA.
  • Colorado Association in Medical Physics, Denver, Colorado, USA.

ORCID-Profile: Nicholas Rancilio, Parminder S Basran

Zitieren

APA

Giapintzaki, K. J., Leary, D., Lee, T. B., Linn, M., Rancilio, N., Shah, I., & Basran, P. S. (2026). Scope of Adoption of Standardized Structure Nomenclature in Veterinary Radiation Oncology. Veterinary Radiology & Ultrasound. https://doi.org/10.1111/vru.70168

Vancouver

Giapintzaki KJ, Leary D, Lee TB, Linn M, Rancilio N, Shah I, et al. Scope of Adoption of Standardized Structure Nomenclature in Veterinary Radiation Oncology. Veterinary Radiology & Ultrasound. 2026. doi:10.1111/vru.70168

BibTeX
@article{Giapintzaki2026,
  author = {Giapintzaki, Konstantina J and Leary, Del and Lee, Thomas Ber-In and Linn, Melanie and Rancilio, Nicholas and Shah, Imran and Basran, Parminder S},
  title = {Scope of Adoption of Standardized Structure Nomenclature in Veterinary Radiation Oncology},
  journal = {Veterinary Radiology & Ultrasound},
  year = {2026},
  doi = {10.1111/vru.70168}
}
Kostenlos starten →