EUVIMEDEUVIMED entdecken
Vergleichsstudie

Magnetic resonance imaging signal changes at the intramuscular injection site in dogs: Comparison of medetomidine and saline

Sojeong Kwon, Daji Noh, Kazutaka Yamada iD, Sang-Kwon Lee iD, Hojung Choi, Youngwon Lee iD, Kija Lee iD

Veterinary Radiology & Ultrasound · 2024

DOI: 10.1111/vru.13438 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Radiology & Ultrasound, 2024. Verfasst von Sojeong Kwon und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Veterinary Medicine, Kyungpook National University, Daegu, South Korea. Hauptthemen laut MEDLINE: Medetomidine, Magnetic Resonance Imaging. Die Arbeit nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intramuscular administration is a commonly used method for delivering sedatives and anesthetics in veterinary medicine. Previous studies have reported inflammation at the intramuscular injection site in laboratory animals and observed signal changes on MRI following intramuscular injections in humans. We hypothesized that following intramuscular injection, the site would exhibit T2 hyperintensity and contrast enhancement on MRI. To investigate this, this prospective study evaluated the pattern of signal changes and grade of T2 signal intensity and contrast enhancement over time after the intramuscular injection of medetomidine at a premedication dosage, comparing it to saline. MRI scans were performed immediately postinjection into the biceps femoris and quadriceps femoris muscles, as well as at 2, 8, 24, and 72 h, and 7 days postinjection. A semiquantitative scale was utilized to grade signal intensity and contrast enhancement. Both medetomidine and saline injections showed T2 hyperintensity immediately after injection and contrast enhancement from 2 h postinjection, manifesting as flame‐shaped. These signal changes decreased up to 24 h postinjection ( p < .05). The signal changes induced by medetomidine showed higher T2 hyperintense change and stronger contrast enhancement compared with saline at most time points, with the signal changes persisting for a longer duration ( p < .05). These findings suggest that intramuscular administration of medetomidine induces a more severe tissue reaction compared with saline, and the results are expected to aid in the differentiation of various muscle diseases that present with similar MRI findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MedetomidineMagnetic Resonance ImagingAnimalsInjections, IntramuscularDogsMaleProspective StudiesFemaleSaline SolutionMuscle, SkeletalHypnotics and Sedatives

Stichwörter der Autor:innen

MR appearancecanineintramuscular administrationsedatives

Substanzen

MedetomidineSaline SolutionHypnotics and Sedatives

Autor:innen und Institutionen

  • College of Veterinary Medicine, Kyungpook National University, Daegu, South Korea.
  • 24 Africa Animal Medical Center, Daejeon, South Korea.
  • Laboratory of Veterinary Radiology, Azabu University, Sagamihara, Japan.
  • College of Veterinary Medicine, Chungnam National University, Daejeon, South Korea.

ORCID-Profile: Kazutaka Yamada, Sang-Kwon Lee, Youngwon Lee, Kija Lee

Zitieren

APA

Kwon, S., Noh, D., Yamada, K., Lee, S. K., Choi, H., Lee, Y., & Lee, K. (2024). Magnetic resonance imaging signal changes at the intramuscular injection site in dogs: Comparison of medetomidine and saline. Veterinary Radiology & Ultrasound. https://doi.org/10.1111/vru.13438

Vancouver

Kwon S, Noh D, Yamada K, Lee SK, Choi H, Lee Y, et al. Magnetic resonance imaging signal changes at the intramuscular injection site in dogs: Comparison of medetomidine and saline. Veterinary Radiology & Ultrasound. 2024. doi:10.1111/vru.13438

BibTeX
@article{Kwon2024,
  author = {Kwon, Sojeong and Noh, Daji and Yamada, Kazutaka and Lee, Sang-Kwon and Choi, Hojung and Lee, Youngwon and Lee, Kija},
  title = {Magnetic resonance imaging signal changes at the intramuscular injection site in dogs: Comparison of medetomidine and saline},
  journal = {Veterinary Radiology & Ultrasound},
  year = {2024},
  doi = {10.1111/vru.13438}
}
Kostenlos starten →