EUVIMEDEUVIMED entdecken
VergleichsstudieBeobachtungsstudieMultizentrische StudieOpen Access · CC BY-NC-ND 4.0

Comparing the volume of umbilical cord blood collection using different techniques

Jip H van Daelen iD, Valeria Cortesi, Lianne I Verbeek, Sophie J E Cramer iD, Elise J Huisman iD, Thomas R L Klei, Irwin K M Reiss, Pauline M Snijder, Enrico Lopriore iD

Vox Sanguinis · 2026-11 · 121 (11) · 1645-1652

DOI: 10.1111/vox.70331 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Vox Sanguinis, online erschienen am 20.07.2026. Verfasst von Jip H van Daelen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neonatology, Department of Pediatrics, Erasmus MC Sophia Children's Hospital, Erasmus Medical University Center, Rotterdam, the Netherlan…. Hauptthemen laut MEDLINE: Fetal Blood, Blood Specimen Collection. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Stichting Vrienden van het Sophia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives Umbilical cord blood (UCB) as a source for red blood cell (RBC) transfusions is a promising alternative to adult RBC transfusions in extremely preterm neonates, as UCB contains predominantly fetal haemoglobin (HbF). A limitation to clinical use is the low and variable yield of UCB collections. This study aimed to assess UCB collection volume and feasibility across three techniques in uncomplicated term pregnancies. Materials and Methods We conducted a prospective observational study in two centres in The Netherlands. We compared the volume of UCB units collected from uncomplicated term deliveries using three different techniques: in utero, ex utero with a funnel and ex utero with a plateau. A minimum target volume of 70 mL was deemed adequate for further processing.

Results

Of 606 collection attempts, 570 (94%) were successful. The median UCB volume was 65 mL (interquartile range, IQR 49–84), with 242 (42.5%) collections ≥70 mL. Volumes differed significantly between the three techniques, with the ex utero plateau technique yielding the highest median volume (70 mL, IQR 55–88), followed by in utero (56 mL, IQR 45–71) and the funnel technique (36 mL, IQR 30–51) ( p < 0.001). UCB volume correlated with birth weight ( p < 0.001), but not with gestational age or sex. Volumes obtained with the plateau technique increased over time, suggesting a learning‐curve effect.

Conclusion

Collected UCB volume was highest using the ex utero plateau technique and was associated with birth weight and operator experience. The observed learning curve underscores the importance of dedicated teams to maximize UCB collection efficiency for future transfusion use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fetal BloodBlood Specimen CollectionHumansFemaleProspective StudiesPregnancyInfant, NewbornNetherlandsMaleAdultErythrocyte Transfusion

Stichwörter der Autor:innen

collection techniquescord‐blood derived red blood cell transfusionsumbilical cord blood

Autor:innen und Institutionen

  • Division of Neonatology, Department of Pediatrics, Erasmus MC Sophia Children's Hospital, Erasmus Medical University Center, Rotterdam, the Netherlands.
  • Neonatal Intensive Care Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
  • Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, the Netherlands.
  • Division of Pediatric Hematology, Department of Pediatrics, Erasmus MC Sophia Children's Hospital, Erasmus Medical University Center, Rotterdam, the Netherlands.
  • Department of Medical Affairs, Unit of Transfusion Medicine, Sanquin Blood Bank, Amsterdam, the Netherlands.
  • Department of Product and Process Development, Sanquin Blood Supply, Amsterdam, the Netherlands.

ORCID-Profile: Jip H van Daelen, Sophie J E Cramer, Elise J Huisman, Enrico Lopriore

Förderung

  • Stichting Vrienden van het Sophia

Zitieren

APA

van Daelen, J. H., Cortesi, V., Verbeek, L. I., Cramer, S. J. E., Huisman, E. J., Klei, T. R. L., Reiss, I. K. M., Snijder, P. M., & Lopriore, E. (2026). Comparing the volume of umbilical cord blood collection using different techniques. Vox Sanguinis, 121(11), 1645-1652. https://doi.org/10.1111/vox.70331

Vancouver

van Daelen JH, Cortesi V, Verbeek LI, Cramer SJE, Huisman EJ, Klei TRL, et al. Comparing the volume of umbilical cord blood collection using different techniques. Vox Sanguinis. 2026;121(11):1645-1652. doi:10.1111/vox.70331

BibTeX
@article{vanDaelen2026,
  author = {van Daelen, Jip H and Cortesi, Valeria and Verbeek, Lianne I and Cramer, Sophie J E and Huisman, Elise J and Klei, Thomas R L and Reiss, Irwin K M and Snijder, Pauline M and Lopriore, Enrico},
  title = {Comparing the volume of umbilical cord blood collection using different techniques},
  journal = {Vox Sanguinis},
  year = {2026},
  volume = {121},
  number = {11},
  pages = {1645--1652},
  doi = {10.1111/vox.70331}
}
Kostenlos starten →