EUVIMEDEUVIMED entdecken
Open Access

In vivo recovery and in vitro quality assessment of apheresis red blood cells stored for 42 days in non‐ DEHP disposable sets

Bethany L Brown iD, Samatha E Mack, Emily Mason, Michael Wellington, Neeta Rugg, Susanne Marschner iD, Christina Gloor, Rebecca L Sedjo, Nero Evero, Joseph Rice, Jeremiah Gorman, Jack P Rhodes und 2 weitere

Vox Sanguinis · 2026-08 · 121 (8) · 1173-1180

DOI: 10.1111/vox.70289 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vox Sanguinis, online erschienen am 24.05.2026. Verfasst von Bethany L Brown und 13 weiteren Autor:innen. Beteiligte Einrichtung: American Red Cross Biomedical Services, Medical and Scientific Office, Washington, DC, USA. Hauptthemen laut MEDLINE: Erythrocytes, Blood Preservation, Blood Component Removal. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Terumo BCT.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives Di(2‐ethylhexyl) phthalate (DEHP) has been used in blood bag manufacturing for decades, but concern about its potential toxicity has prompted regulatory efforts to eliminate it from medical devices, including blood bags. As manufacturers transition to non‐DEHP materials, evaluation is required to ensure blood component quality in modified bag systems. Investigational Trima Accel disposables were developed using plasticizers approved as DEHP alternatives per the European Pharmacopoeia. Red blood cells (RBCs) were collected, and two consecutive studies evaluated in vitro quality and in vivo RBC recovery. Study Design and Methods Leukoreduced RBCs (LR‐RBCs) were stored in Additive Solution 3 (AS‐3) at 2–6°C for 42 days. In vitro quality parameters measured on days 0, 35 and/or 42 were assessed against US Food and Drug Administration (FDA) and European Directorate for the Quality of Medicines & HealthCare (EDQM) acceptance criteria. A radiolabelling study evaluated in vivo 24‐h RBC recovery using the FDA criteria.

Results

Key FDA criteria were met, including haemolysis, which remained below the acceptable limit throughout 42 days of storage. All EDQM criteria were met except Day 0 haematocrit, with 8 units outside the specified range and the confidence interval (CI) lower bound at 77.6%. All FDA criteria for in vivo 24‐h RBC recovery were met.

Conclusion

Apheresis LR‐RBCs collected with Trima Accel systems using non‐DEHP disposables and stored for 42 days met key FDA and EDQM criteria, with any in vitro parameter failures considered artefactual. Products also met FDA's 24‐h in vivo RBC recovery criteria, supporting their use as acceptable transfusable products.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ErythrocytesBlood PreservationBlood Component RemovalHumansTime FactorsHemolysis

Stichwörter der Autor:innen

in vivo red cell recoverynon‐DEHP plasticizerred blood cells

Autor:innen und Institutionen

  • American Red Cross Biomedical Services, Medical and Scientific Office, Washington, DC, USA.
  • Vitalant Research Institute, Denver, Colorado, USA.
  • Terumo BCT, Inc., Lakewood, Colorado, USA.
  • Hoxworth Blood Center, Cincinnati, Ohio, USA.
  • Lifetime Scientific, Inc., Dundas, Canada.

ORCID-Profile: Bethany L Brown, Susanne Marschner, Caroline Alquist

Förderung

  • Terumo BCT

Zitieren

APA

Brown, B. L., Mack, S. E., Mason, E., Wellington, M., Rugg, N., Marschner, S., Gloor, C., Sedjo, R. L., Evero, N., Rice, J., Gorman, J., Rhodes, J. P., Cook, R., & Alquist, C. (2026). In vivo recovery and in vitro quality assessment of apheresis red blood cells stored for 42 days in non‐ DEHP disposable sets. Vox Sanguinis, 121(8), 1173-1180. https://doi.org/10.1111/vox.70289

Vancouver

Brown BL, Mack SE, Mason E, Wellington M, Rugg N, Marschner S, et al. In vivo recovery and in vitro quality assessment of apheresis red blood cells stored for 42 days in non‐ DEHP disposable sets. Vox Sanguinis. 2026;121(8):1173-1180. doi:10.1111/vox.70289

BibTeX
@article{Brown2026,
  author = {Brown, Bethany L and Mack, Samatha E and Mason, Emily and Wellington, Michael and Rugg, Neeta and Marschner, Susanne and Gloor, Christina and Sedjo, Rebecca L and Evero, Nero and Rice, Joseph and Gorman, Jeremiah and Rhodes, Jack P and Cook, Richard and Alquist, Caroline},
  title = {In vivo recovery and in vitro quality assessment of apheresis red blood cells stored for 42 days in non‐ DEHP disposable sets},
  journal = {Vox Sanguinis},
  year = {2026},
  volume = {121},
  number = {8},
  pages = {1173--1180},
  doi = {10.1111/vox.70289}
}
Kostenlos starten →