EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Evaluating compliance with restrictive blood transfusion practices: A 5‐year study from a Greek tertiary hospital

Georgios K Nikolopoulos, Athena Koutoulogeni iD, Elias Kyriakou, Stavros Tsalas, Anastasia Papandreadi, Panagiota Douramani, Styliani I Kokoris, Electra Loukopoulou, Aimilia Tsante, Athina Kypraiou, Aristarchos Poulis, Stefanos Bonovas iD und 2 weitere

Vox Sanguinis · 2026

DOI: 10.1111/vox.70184 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vox Sanguinis, 2026. Verfasst von Georgios K Nikolopoulos und 13 weiteren Autor:innen. Beteiligte Einrichtung: Medical School, University of Cyprus, Nicosia, Cyprus. Hauptthemen laut MEDLINE: Blood Transfusion, Guideline Adherence. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives Our aim was to retrospectively assess the adherence to a restrictive transfusion strategy (in the context of patient blood management [PBM]) among patients in a Greek tertiary hospital over a 5‐year period (2020–2024) following the initial evaluation of the electronic transfusion request system. Materials and Methods Analyses included assessment of time trends—overall and by hospital clinic—in haemoglobin (Hb) levels at transfusion, as well as in the proportion of inappropriate transfusions, based on pre‐specified audit criteria (Hb thresholds for red blood cell transfusions).

Results

A total of 23,322 transfusion episodes were recorded among medical patients, with annual counts ranging from 4078 to 5394 and an overall mean transfusion Hb level of 7.18 ± 0.78 g/dL. The proportion of transfusions with Hb levels above 7.00 g/dL decreased significantly from 69.14% in 2020 to 58.83% in 2023 (Cochran–Armitage test for trend, p < 0.01). Among patients without comorbidities (threshold: 7.00 g/dL), 53.34% of transfusions occurred above this cut‐off, with an initial drop from 60.41% in 2020 to 47.72% in 2021, followed by a rebound to 58.43% in 2024 ( p = 0.25). Transfusions above 8.00 g/dL also declined significantly, from 8.33% in 2020 to 5.20% in 2023 ( p < 0.01). Differences were also observed among clinics.

Conclusion

Overall, moderate compliance with the restrictive transfusion strategy was observed. The initial decline in transfusions above prespecified Hb thresholds followed by fluctuations in subsequent years highlights the need for a consistent, multifaceted effort to optimize blood usage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood TransfusionGuideline AdherenceHumansGreeceTertiary Care CentersRetrospective StudiesFemaleMaleHemoglobinsMiddle AgedAged

Stichwörter der Autor:innen

blood usage optimizationelectronic transfusion orderpatient blood managementrestrictive transfusion strategyretrospective audit

Substanzen

Hemoglobins

Autor:innen und Institutionen

  • Medical School, University of Cyprus, Nicosia, Cyprus.
  • Laboratory of Hematology and Blood Bank Unit, Attikon University Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
  • Information Technology Department, Attikon University Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
  • Department of Biomedical Sciences, Humanitas University, Milan, Italy.
  • IRCCS Humanitas Research Hospital, Milan, Italy.
  • Laboratory of Reliability and Quality Control in Laboratory Hematology (HemQcR), Department of Biomedical Sciences, School of Health & Caring Sciences, University of West Attica (UniWA), Aigaleo, Greece.

ORCID-Profile: Athena Koutoulogeni, Stefanos Bonovas, Anastasios Kriebardis

Zitieren

APA

Nikolopoulos, G. K., Koutoulogeni, A., Kyriakou, E., Tsalas, S., Papandreadi, A., Douramani, P., Kokoris, S. I., Loukopoulou, E., Tsante, A., Kypraiou, A., Poulis, A., Bonovas, S., Kriebardis, A., & Tsantes, A. E. (2026). Evaluating compliance with restrictive blood transfusion practices: A 5‐year study from a Greek tertiary hospital. Vox Sanguinis. https://doi.org/10.1111/vox.70184

Vancouver

Nikolopoulos GK, Koutoulogeni A, Kyriakou E, Tsalas S, Papandreadi A, Douramani P, et al. Evaluating compliance with restrictive blood transfusion practices: A 5‐year study from a Greek tertiary hospital. Vox Sanguinis. 2026. doi:10.1111/vox.70184

BibTeX
@article{Nikolopoulos2026,
  author = {Nikolopoulos, Georgios K and Koutoulogeni, Athena and Kyriakou, Elias and Tsalas, Stavros and Papandreadi, Anastasia and Douramani, Panagiota and Kokoris, Styliani I and Loukopoulou, Electra and Tsante, Aimilia and Kypraiou, Athina and Poulis, Aristarchos and Bonovas, Stefanos and Kriebardis, Anastasios and Tsantes, Argirios E},
  title = {Evaluating compliance with restrictive blood transfusion practices: A 5‐year study from a Greek tertiary hospital},
  journal = {Vox Sanguinis},
  year = {2026},
  doi = {10.1111/vox.70184}
}
Kostenlos starten →