The effect of plasma donation frequency on total serum protein, immunoglobulin G and donor safety: A non‐inferiority randomized controlled trial
Vox Sanguinis · 2025
DOI: 10.1111/vox.70105 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Vox Sanguinis, 2025. Verfasst von Morten Haugen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Innlandet Hospital Trust, Brumunddal, Norway. Hauptthemen laut MEDLINE: Blood Donors, Immunoglobulin G, Blood Proteins, Plasma. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Sykehuset Innlandet HF.
Abstract (Originalsprache)
Background and Objectives The safety of varying plasma donation frequencies remains unclear. This non‐inferiority randomized controlled trial investigated the effect of plasma donation frequency on total serum protein (TSP), immunoglobulin G (IgG) concentrations, additional biomarkers, adverse events (AEs) and psychological distress. Materials and Methods In this trial, 120 male donors were randomized into three groups: high‐frequency plasma donors (HFPDs, three times every 2 weeks), regular‐frequency plasma donors (RFPDs, once every 2 weeks) and a control group (whole blood donation every 3 months). Blood samples were collected biweekly from baseline until the last donation in Week 16 and 4 weeks after the last donation.
Results
HFPDs completed median (range) 21.5 (1–24), RFPDs 8 (1–8) and controls 2 (1–2) donations. HFPDs had lower concentrations of TSP and IgG compared to controls, with a mean difference (95% confidence interval [CI]) of −5.5 g/L (−7.4, −3.6) and −2.8 g/L (−3.8, −1.8), respectively. Within‐group analysis revealed significant reductions, which increased with the frequency of donations, in TSP, IgG, IgG subclasses, immunoglobulin M (IgM), immunoglobulin A (IgA), ferritin and haemoglobin. Many of the biomarkers required more than 4 weeks to return to baseline levels. Only mild AEs were reported, and plasma donation frequency had no effect on psychological distress.
Conclusion
High‐ and regular‐frequency plasmapheresis substantially reduces concentrations of TSP, IgG and other biomarkers, with greater reductions at higher donation frequencies. Further research is needed to assess the long‐term health implications of frequent plasma donation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Innlandet Hospital Trust, Brumunddal, Norway.
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway.
- Oslo University Hospital, Oslo, Norway.
ORCID-Profile: Morten Haugen, Karin Magnussen
Förderung
- Sykehuset Innlandet HF
Zitieren
APA
Haugen, M., Nissen-Meyer, L. S. H., Strand, T. A., & Magnussen, K. (2025). The effect of plasma donation frequency on total serum protein, immunoglobulin G and donor safety: A non‐inferiority randomized controlled trial. Vox Sanguinis. https://doi.org/10.1111/vox.70105
Vancouver
Haugen M, Nissen-Meyer LSH, Strand TA, Magnussen K. The effect of plasma donation frequency on total serum protein, immunoglobulin G and donor safety: A non‐inferiority randomized controlled trial. Vox Sanguinis. 2025. doi:10.1111/vox.70105
BibTeX
@article{Haugen2025,
author = {Haugen, Morten and Nissen-Meyer, Lise Sofie Haug and Strand, Tor A and Magnussen, Karin},
title = {The effect of plasma donation frequency on total serum protein, immunoglobulin G and donor safety: A non‐inferiority randomized controlled trial},
journal = {Vox Sanguinis},
year = {2025},
doi = {10.1111/vox.70105}
}