EUVIMEDEUVIMED entdecken
Crossref

Lipaemic plasma: An objective non‐invasive photometric method to classify plasma turbidity and its association with red cell haemolysis

Lara A E de Laleijne-Liefting iD, Ido J Bontekoe iD, Johan W Lagerberg, Thomas R L Klei iD

Vox Sanguinis · 2025

DOI: 10.1111/vox.13778 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Vox Sanguinis, 2025. Verfasst von Lara A E de Laleijne-Liefting und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Product and Process Development, Sanquin Blood Bank, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Hemolysis, Plasma, Erythrocytes, Photometry. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives Plasma components are visually inspected, and non‐transparent, turbid units are rejected for transfusion and fractionation. Additionally, in case a plasma component is deemed lipaemic, there is conflicting data on the accompanying red cell concentrate (RCC) in vitro quality. As visual inspection of plasma turbidity is a subjective method, we aimed to devise an objective measurement using a quick, non‐invasive, table‐top spectrophotometry‐based method. Using this method, the correlation between spectrophotometric data and its predictive value on haemolysis of the accompanying RCC during storage was assessed. Materials and Methods A total of 365 plasma units were visually inspected for turbidity and analysed for light reflection parameters ( L *, a * and b *) and triglyceride (TG) levels. Leukoreduced RCCs in saline‐adenine‐glucose‐mannitol (SAGM), prepared from the accompanying lipaemic whole blood, were stored for up to 6 weeks and analysed for quality parameters.

Results

The light reflection L * value was the most discriminating between clear and turbid/lipaemic plasma. Also, a correlation was found between TG levels and L * values ( R 2 = 0.703). Plasma with TG ≥ 2.5 mmol/L showed an L * value >50 with >90% specificity and sensitivity. RCC from donations with a plasma L * value ≥68 showed significantly higher haemolysis levels ( p < 0.05) during storage.

Conclusion

The non‐invasive photometric analysis of plasma turbidity correlated both with visual inspection and plasma TG levels. Measurement of L * values of plasma may be helpful in identifying donations with high TG levels and higher risk for increased haemolysis during RCC storage.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HemolysisPlasmaErythrocytesPhotometryHumansTriglyceridesBlood Preservation

Stichwörter der Autor:innen

colour measurementhaemolysisred cell concentratestriglyceridesturbid plasma

Substanzen

Triglycerides

Autor:innen und Institutionen

  • Department of Product and Process Development, Sanquin Blood Bank, Amsterdam, the Netherlands.

ORCID-Profile: Lara A E de Laleijne-Liefting, Ido J Bontekoe, Thomas R L Klei

Zitieren

APA

de Laleijne-Liefting, L. A. E., Bontekoe, I. J., Lagerberg, J. W., & Klei, T. R. L. (2025). Lipaemic plasma: An objective non‐invasive photometric method to classify plasma turbidity and its association with red cell haemolysis. Vox Sanguinis. https://doi.org/10.1111/vox.13778

Vancouver

de Laleijne-Liefting LAE, Bontekoe IJ, Lagerberg JW, Klei TRL. Lipaemic plasma: An objective non‐invasive photometric method to classify plasma turbidity and its association with red cell haemolysis. Vox Sanguinis. 2025. doi:10.1111/vox.13778

BibTeX
@article{deLaleijneLiefting2025,
  author = {de Laleijne-Liefting, Lara A E and Bontekoe, Ido J and Lagerberg, Johan W and Klei, Thomas R L},
  title = {Lipaemic plasma: An objective non‐invasive photometric method to classify plasma turbidity and its association with red cell haemolysis},
  journal = {Vox Sanguinis},
  year = {2025},
  doi = {10.1111/vox.13778}
}
Kostenlos starten →