Characterization of a novel mouse platelet transfusion model
Vox Sanguinis · 2024-07 · 119 (7) · 702-711
DOI: 10.1111/vox.13642 ↗Kurz gefasst
Fachartikel in der Zeitschrift Vox Sanguinis, online erschienen am 21.04.2024. Verfasst von Dominique Gordy und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology and Cell Biology, Columbia University Irving Medical Center, New York, New York, USA. Hauptthemen laut MEDLINE: Platelet Transfusion, Blood Platelets, Blood Preservation. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Columbia University Department of Pathology and Cell Biology, Herbert Irving Comprehensive Cancer Center at Columbia University, NIH/NCI Cancer Center.
Abstract (Originalsprache)
Background and Objectives Platelet transfusions are increasing with medical advances. Based on FDA criteria, platelet units are assessed by in vitro measures; however, it is not known how platelet processing and storage duration affect function in vivo. Our study's aim was to develop a novel platelet transfusion model stored in mouse plasma that meets FDA criteria adapted to mice, and transfused fresh and stored platelets are detectable in clots in vivo. Study Design and Methods Platelet units stored in mouse plasma were prepared using a modified platelet‐rich plasma (PRP) collection protocol. Characteristics of fresh and stored units, including pH, cell count, in vitro measures of activity, including activation and aggregation, and post‐transfusion recovery (PTR), were determined. Lastly, a tail transection assay was conducted using mice transfused with fresh or stored units, and transfused platelets were identified by confocal imaging.
Results
Platelet units had acceptable platelet and white cell counts and were negative for bacterial contamination. Fresh and 1‐day stored units had acceptable pH; the platelets were activatable by thrombin and adenosine diphosphate, agreeable with thrombin, had acceptable PTR, and were present in vivo in clots of recipients after tail transection. In contrast, 2‐day stored units had clinically unacceptable quality.
Conclusion
We developed mouse platelets for transfusion analogous to human platelet units using a modified PRP collection protocol with maximum storage of 1 day for an ‘old’ unit. This provides a powerful tool to test how process modifications and storage conditions affect transfused platelet function in vivo.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pathology and Cell Biology, Columbia University Irving Medical Center, New York, New York, USA.
ORCID-Profile: Elizabeth F Stone
Förderung
- Columbia University Department of Pathology and Cell Biology
- Herbert Irving Comprehensive Cancer Center at Columbia University
- NIH/NCI Cancer Center
Zitieren
APA
Gordy, D., Swayne, T., Berry, G. J., Thomas, T. A., Hudson, K. E., & Stone, E. F. (2024). Characterization of a novel mouse platelet transfusion model. Vox Sanguinis, 119(7), 702-711. https://doi.org/10.1111/vox.13642
Vancouver
Gordy D, Swayne T, Berry GJ, Thomas TA, Hudson KE, Stone EF. Characterization of a novel mouse platelet transfusion model. Vox Sanguinis. 2024;119(7):702-711. doi:10.1111/vox.13642
BibTeX
@article{Gordy2024,
author = {Gordy, Dominique and Swayne, Theresa and Berry, Gregory J and Thomas, Tiffany A and Hudson, Krystalyn E and Stone, Elizabeth F},
title = {Characterization of a novel mouse platelet transfusion model},
journal = {Vox Sanguinis},
year = {2024},
volume = {119},
number = {7},
pages = {702--711},
doi = {10.1111/vox.13642}
}