Analysis of maternal Fc gamma receptor IIIb isoantibodies using immunomagnetic negative selected neutrophils
Vox Sanguinis · 2024
DOI: 10.1111/vox.13631 ↗Kurz gefasst
Fachartikel in der Zeitschrift Vox Sanguinis, 2024. Verfasst von Juliana Oliveira Martins und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical and Experimental Oncology, Universidade Federal de São Paulo, UNIFESP, São Paulo, Brazil. Hauptthemen laut MEDLINE: Isoantibodies, Neutrophils, Receptors, IgG. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Background and Objectives The isolation of neutrophils and subsequent detection of anti‐human neutrophil antigens (HNA) antibodies are crucial in clinical medicine for the diagnosis of autoimmune neutropenia, neonatal alloimmune neutropenia (NAIN) and transfusion‐related acute lung injury (TRALI). This study reports two cases of maternal anti‐Fc‐gamma‐receptor‐IIIb (FcγRIIIb) isoimmunization without NAIN symptoms and compares the efficiency of immunomagnetic negative selection (IMNS) with traditional dextran/Ficoll for neutrophil isolation in HNA serological assays. Materials and Methods Investigating two cases of maternal anti‐FcγRIIIb isoimmunization, neutrophils from three donors were isolated from 8 mL of whole blood using IMNS and dextran/Ficoll. Serological assays included the granulocyte agglutination and immunofluorescence test, monoclonal antibody immobilization of granulocyte antigens and the LABScreen Multi (One Lambda). IMNS and dextran/Ficoll were compared in terms of cell yield, viability, time, cost and purity.
Results
Maternal anti‐FcγRIIIb isoantibodies with FCGR3B gene deletion were detected in both cases. Newborns and fathers exhibited specific gene combinations: FCGR3B*02/FCGR3B*02 (Case 1) and FCGR3B*02/FCGR3B*03 (Case 2). IMNS outperformed dextran/Ficoll, yielding four times more neutrophils (average neutrophil counts: 18.5 × 10 3 /μL vs. 4.5 × 10 3 /μL), efficiently removing non‐neutrophil cells and reducing processing time (30–40 min vs. 70–90 min), although it incurred a higher cost (2.7 times).
Conclusion
Two cases of maternal anti‐FcγRIIIb isoantibodies, unrelated to NAIN, were identified. Although neutropenia has not been described in these cases, we emphasize the importance of identifying asymptomatic cases with the potential for severe neutropenia. Additionally, IMNS is introduced as a rapid, high‐yield, high‐purity neutrophil isolation technique, beneficial for serological assays detecting anti‐HNA antibodies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical and Experimental Oncology, Universidade Federal de São Paulo, UNIFESP, São Paulo, Brazil.
- Hospital Geral de Guarulhos, São Paulo, Brazil.
- Institute for Clinical Immunology, Transfusion Medicine, and Haemostasis, Justus Liebig University, Giessen, Germany.
- Instituto de Imunogenética, IGEN, São Paulo, Brazil.
ORCID-Profile: Elyse Moritz, Behnaz Bayat
Förderung
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Martins, J. O., Moritz, E., Abbas, S. A., Bayat, B., Barros, M. M. O., de Marco, R., Machado, R. F., & Bordin, J. O. (2024). Analysis of maternal Fc gamma receptor IIIb isoantibodies using immunomagnetic negative selected neutrophils. Vox Sanguinis. https://doi.org/10.1111/vox.13631
Vancouver
Martins JO, Moritz E, Abbas SA, Bayat B, Barros MMO, de Marco R, et al. Analysis of maternal Fc gamma receptor IIIb isoantibodies using immunomagnetic negative selected neutrophils. Vox Sanguinis. 2024. doi:10.1111/vox.13631
BibTeX
@article{Martins2024,
author = {Martins, Juliana Oliveira and Moritz, Elyse and Abbas, Samira Ali and Bayat, Behnaz and Barros, Melca Maria Oliveira and de Marco, Renato and Machado, Renata Fantini and Bordin, José Orlando},
title = {Analysis of maternal Fc gamma receptor IIIb isoantibodies using immunomagnetic negative selected neutrophils},
journal = {Vox Sanguinis},
year = {2024},
doi = {10.1111/vox.13631}
}
EUVIMED