Measurement of Anions in Dog Tear Fluid Using Ion Chromatography
Veterinary Ophthalmology · 2026-09 · 29 (5)
DOI: 10.1111/vop.70262 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Ophthalmology, online erschienen am 04.09.2026. Verfasst von Tomohiko Saito und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Toho University Omori Medical Center, Ota, Tokyo, Japan. Hauptthemen laut MEDLINE: Tears, Anions. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
Anions in tears may be related to the pathogenesis of ocular surface diseases. A comprehensive method that can detect small quantities of anions in human tears has been developed. However, the differences in individual anion concentrations between tears and plasma remain unclear. This study investigated anion concentrations in dog tears.
Methods
To compare anion concentrations between tear and plasma samples in canines, 12 eyes of six healthy purpose‐bred research Beagles (unneutered males, 3 years old) were investigated. Additionally, the tears of canines with various diseases were examined. Procedure: Anion concentrations were assessed using a commercially available ion chromatography system. For this, at least 10 μL of tears were collected in a glass capillary tube and diluted with 300 μL of distilled water; plasma was obtained by centrifuging collected blood samples, which were then diluted 100‐fold before chromatography.
Results
Anion concentrations differed significantly between the tears and plasma of Beagles. The average concentrations (mg/L) of anions in tears of Beagles were as follows: Cl − , 5374.06 ± 157.06; Br − , 27.84 ± 1.43; NO 3 − , 0.70 ± 0.65; HPO 4 2− , 77.54 ± 14.36; and SO 4 2− , 16.41 ± 8.17. In plasma, the values were as follows: Cl − , 4603.81 ± 542.52; Br − , 18.34 ± 2.78; NO 3 − , 1.31 ± 0.87; HPO 4 2− , 83.63 ± 21.04; and SO 4 2− , 105.14 ± 21.86. No statistically significant differences in anion concentrations were observed between tears from diseased and non‐diseased eyes of canines.
Conclusions
Herein, we observed that certain anions, such as Br − and Cl − , were consistently elevated in tear fluid than in the plasma.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Toho University Omori Medical Center, Ota, Tokyo, Japan.
- Department of Veterinary Medicine, College of Bioresource Sciences, Nihon University, Fujisawa, Kanagawa, Japan.
ORCID-Profile: Tomohiko Saito, Takashi Suzuki, Takanori Narita, Ken Okabayashi, Yuichi Hori
Zitieren
APA
Saito, T., Suzuki, T., Kato, Y., Narita, T., Okabayashi, K., & Hori, Y. (2026). Measurement of Anions in Dog Tear Fluid Using Ion Chromatography. Veterinary Ophthalmology, 29(5). https://doi.org/10.1111/vop.70262
Vancouver
Saito T, Suzuki T, Kato Y, Narita T, Okabayashi K, Hori Y. Measurement of Anions in Dog Tear Fluid Using Ion Chromatography. Veterinary Ophthalmology. 2026;29(5). doi:10.1111/vop.70262
BibTeX
@article{Saito2026,
author = {Saito, Tomohiko and Suzuki, Takashi and Kato, Yukina and Narita, Takanori and Okabayashi, Ken and Hori, Yuichi},
title = {Measurement of Anions in Dog Tear Fluid Using Ion Chromatography},
journal = {Veterinary Ophthalmology},
year = {2026},
volume = {29},
number = {5},
doi = {10.1111/vop.70262}
}
EUVIMED