EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of the Ovine Corneal Endothelium Using a Human Eye Bank Specular Microscope

Tanise Carboni da Silva, Sofia da Fonseca Lopes Pinto, Alana Pinto de Melo, Marcelle Bettio, Diane Ruschel Marinho iD, Felipe Silva Guareze, João Antonio Tadeu Pigatto iD

Veterinary Ophthalmology · 2026-07 · 29 (4)

DOI: 10.1111/vop.70190 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Ophthalmology, online erschienen am 19.05.2026. Verfasst von Tanise Carboni da Silva und 6 weiteren Autor:innen. Beteiligte Einrichtung: Veterinary College, Federal University of Rio Grande do Sul, UFRGS, Porto Alegre, RS, Brazil. Hauptthemen laut MEDLINE: Endothelium, Corneal, Microscopy, Eye Banks. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate the feasibility of visualizing and quantitatively analyzing the corneal endothelium of sheep using a specular microscope designed for a human eye bank. Twenty‐four healthy corneas from 12 one‐year‐old male sheep ( Ovis aries ) were examined. Four central endothelial images per cornea were analyzed using a semi‐automated method. Endothelial parameters were automatically calculated by the proprietary software integrated into the specular microscope, including endothelial cell density (ECD), average cell area (AVE), coefficient of variation (CV) in cell size, and percentage of hexagonal cells (HEX). Data normality was assessed using the Kolmogorov–Smirnov test, and paired comparisons between right and left eyes were performed using Student's t ‐test. High‐quality endothelial images were successfully obtained from all corneas. The mean ECD was 3198.3 ± 428.3 cells/mm 2 , AVE was 318.7 ± 42.3 μm 2 , CV in cell size was 38.0% ± 7.9%, and HEX was 57.7%. No statistically significant differences were observed between right and left eyes for any parameter ( p > 0.05). A human eye bank specular microscope allows reliable visualization and quantitative assessment of the ovine corneal endothelium, demonstrating its applicability in experimental and translational veterinary ophthalmology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endothelium, CornealMicroscopyEye BanksAnimalsMaleSheepCell CountHumans

Stichwörter der Autor:innen

corneal endotheliumcorneal transplantationendothelial cell densityeye bank specular microscopysheepspecular microscopyveterinary ophthalmology

Autor:innen und Institutionen

  • Veterinary College, Federal University of Rio Grande do Sul, UFRGS, Porto Alegre, RS, Brazil.
  • Hospital de Clínicas de Porto Alegre (HCPA), Porto Alegre, RS, Brazil.

ORCID-Profile: Diane Ruschel Marinho, João Antonio Tadeu Pigatto

Zitieren

APA

da Silva, T. C., da Fonseca Lopes Pinto, S., de Melo, A. P., Bettio, M., Marinho, D. R., Guareze, F. S., & Pigatto, J. A. T. (2026). Evaluation of the Ovine Corneal Endothelium Using a Human Eye Bank Specular Microscope. Veterinary Ophthalmology, 29(4). https://doi.org/10.1111/vop.70190

Vancouver

da Silva TC, da Fonseca Lopes Pinto S, de Melo AP, Bettio M, Marinho DR, Guareze FS, et al. Evaluation of the Ovine Corneal Endothelium Using a Human Eye Bank Specular Microscope. Veterinary Ophthalmology. 2026;29(4). doi:10.1111/vop.70190

BibTeX
@article{daSilva2026,
  author = {da Silva, Tanise Carboni and da Fonseca Lopes Pinto, Sofia and de Melo, Alana Pinto and Bettio, Marcelle and Marinho, Diane Ruschel and Guareze, Felipe Silva and Pigatto, João Antonio Tadeu},
  title = {Evaluation of the Ovine Corneal Endothelium Using a Human Eye Bank Specular Microscope},
  journal = {Veterinary Ophthalmology},
  year = {2026},
  volume = {29},
  number = {4},
  doi = {10.1111/vop.70190}
}
Kostenlos starten →