EUVIMEDEUVIMED entdecken
Fallbericht

Removal of an anterior chamber foreign body using hydropulsion and ophthalmic viscoelastic device capture in a dog

K Tomo Wiggans iD

Veterinary Ophthalmology · 2025

DOI: 10.1111/vop.13251 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Veterinary Ophthalmology, 2025. Verfasst von K Tomo Wiggans. Beteiligte Einrichtung: Sage Veterinary Centers, Concord, California, USA. Hauptthemen laut MEDLINE: Anterior Chamber, Eye Foreign Bodies, Dog Diseases. Die Arbeit nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To describe the removal of an adherent, presumed plant‐based, anterior chamber foreign body (ACFB) from the inferior iridocorneal angle in a dog using hydropulsion and ophthalmic viscoelastic device (OVD) capture. Animal Studied A 6‐year‐old female spayed pit bull terrier who was referred for further evaluation of a corneal opacity after being observed running into a thorned succulent plant 1 month earlier. On ophthalmic examination, no corneal foreign body was noted, though mild uveitis was present. Gonioscopy revealed a suspected plant foreign body (thorn tip) in the inferior iridocorneal angle. Procedure Under general anesthesia, the ACFB was dislodged from the inferior iridocorneal angle using hydropulsion with balanced salt solution. The superior half of the anterior chamber had been filled with 2% hydroxypropyl methylcellulose OVD to trap the foreign object. One month later, the uveitis had resolved and repeat gonioscopy confirmed the absence of any ACFB in the iridocorneal angle.

Conclusion

In the absence of an intraoperative goniolens or endoscopy, hydropulsion and OVD capture of adherent ACFBs may be a feasible option for removal.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anterior ChamberEye Foreign BodiesDog DiseasesAnimalsDogsFemaleGonioscopyViscoelastic Substances

Stichwörter der Autor:innen

gonioscopyhydropulsionintraocular foreign bodyiridocorneal angleocular traumaviscoelastic

Substanzen

Viscoelastic Substances

Autor:innen und Institutionen

  • Sage Veterinary Centers, Concord, California, USA.

ORCID-Profile: K Tomo Wiggans

Zitieren

APA

Wiggans, K. T. (2025). Removal of an anterior chamber foreign body using hydropulsion and ophthalmic viscoelastic device capture in a dog. Veterinary Ophthalmology. https://doi.org/10.1111/vop.13251

Vancouver

Wiggans KT. Removal of an anterior chamber foreign body using hydropulsion and ophthalmic viscoelastic device capture in a dog. Veterinary Ophthalmology. 2025. doi:10.1111/vop.13251

BibTeX
@article{Wiggans2025,
  author = {Wiggans, K Tomo},
  title = {Removal of an anterior chamber foreign body using hydropulsion and ophthalmic viscoelastic device capture in a dog},
  journal = {Veterinary Ophthalmology},
  year = {2025},
  doi = {10.1111/vop.13251}
}
Kostenlos starten →