Comparison of conjunctival pedicle flap to corneal fixation strength achieved by Tisseel® fibrin glue, ethyl cyanoacrylate adhesive, ReSure ® hydrogel sealant, and conventional suturing with 8‐0 VICRYL ® ophthalmic suture

Elodie M VerHulst iD, Roxanne M Rodriguez Galarza iD, Ian P Herring, Renata Velloso Ramos, Andrew R Kemper

Veterinary Ophthalmology · 2025

DOI: 10.1111/vop.13197 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Ophthalmology, 2025. Verfasst von Elodie M VerHulst und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Sciences, Virginia Maryland College of Veterinary Medicine, Virginia Tech, Blacksburg, Virginia, USA. Hauptthemen laut MEDLINE: Tissue Adhesives, Suture Techniques, Conjunctiva, Cornea. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 75 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Veterinary Memorial Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine and compare the fixation strength of conjunctival pedicle flaps to cornea achieved via conventional ophthalmic suture and three different adhesive compounds. Animals Studied Ex vivo porcine globes. Procedures Following a 6 mm wide 500‐micron‐restricted depth lamellar keratectomy, conjunctival pedicle flaps were secured to the keratectomy site with either 8‐0 VICRYL® suture or one of three adhesive products, including Tisseel® bioadhesive, ReSure® synthetic adhesive, or ethyl cyanoacrylate adhesive ( n = 10 per surgical group). Adhesive application protocol varied by product based upon adhesive biocompatibility. Corneoconjunctival tissues were then harvested, clamped in a tensile testing device, and loaded at a rate of 1 mm/s under video surveillance until the point of failure. Peak load was determined for each test and used to compare fixation strength between samples.

Results

Forty conjunctival flaps were performed, with 6 omitted from evaluation due to dehiscence prior to tensile testing. Of the 34 flaps analyzed, 10 were secured with suture, 10 with cyanoacrylate, 8 with ReSure®, and 6 with Tisseel®. Flaps secured with suture withstood significantly higher applied tensile force compared with cyanoacrylate ( p = .02474), ReSure® ( p = .00000), and Tisseel® ( p = .00002). Flaps secured with cyanoacrylate withstood significantly greater force than those secured with ReSure® and Tisseel® ( p = .01194 and 0.01798, respectively). There was no significant difference in fixation strength between ReSure® and Tisseel® glue ( p = .95675).

Conclusions

Conjunctival pedicle flap fixation using 8‐0 VICRYL® suture fixation was able to withstand significantly greater maximum tensile force compared to ReSure®, Tisseel®, or cyanoacrylate adhesives. Fixation strength achieved with cyanoacrylate adhesive was significantly greater than that achieved with ReSure® or Tisseel®.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tissue AdhesivesSuture TechniquesConjunctivaCorneaFibrin Tissue AdhesiveSurgical FlapsAnimalsSwineCyanoacrylatesTensile StrengthSutures

Stichwörter der Autor:innen

conjunctival flapcorneacyanoacrylatefibrin adhesivefixationhydrogel

Substanzen

Tissue AdhesivesCyanoacrylatesFibrin Tissue Adhesive

Autor:innen und Institutionen

  • Department of Small Animal Clinical Sciences, Virginia Maryland College of Veterinary Medicine, Virginia Tech, Blacksburg, Virginia, USA.
  • Department of Biomedical Engineering and Mechanics, College of Engineering, Virginia Tech, Blacksburg, Virginia, USA.

ORCID-Profile: Elodie M VerHulst, Roxanne M Rodriguez Galarza

Förderung

  • Veterinary Memorial Fund

Zitieren

APA

VerHulst, E. M., Galarza, R. M. R., Herring, I. P., Ramos, R. V., & Kemper, A. R. (2025). Comparison of conjunctival pedicle flap to corneal fixation strength achieved by Tisseel® fibrin glue, ethyl cyanoacrylate adhesive, ReSure ® hydrogel sealant, and conventional suturing with 8‐0 VICRYL ® ophthalmic suture. Veterinary Ophthalmology. https://doi.org/10.1111/vop.13197

Vancouver

VerHulst EM, Galarza RMR, Herring IP, Ramos RV, Kemper AR. Comparison of conjunctival pedicle flap to corneal fixation strength achieved by Tisseel® fibrin glue, ethyl cyanoacrylate adhesive, ReSure ® hydrogel sealant, and conventional suturing with 8‐0 VICRYL ® ophthalmic suture. Veterinary Ophthalmology. 2025. doi:10.1111/vop.13197

BibTeX
@article{VerHulst2025,
  author = {VerHulst, Elodie M and Galarza, Roxanne M Rodriguez and Herring, Ian P and Ramos, Renata Velloso and Kemper, Andrew R},
  title = {Comparison of conjunctival pedicle flap to corneal fixation strength achieved by Tisseel® fibrin glue, ethyl cyanoacrylate adhesive, ReSure ® hydrogel sealant, and conventional suturing with 8‐0 VICRYL ® ophthalmic suture},
  journal = {Veterinary Ophthalmology},
  year = {2025},
  doi = {10.1111/vop.13197}
}
Kostenlos starten →