Fachartikel in der Zeitschrift Veterinary Ophthalmology, 2023. Verfasst von Hyun-Wook Kim und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Ophthalmology, College of Veterinary Medicine, Konkuk University, Seoul, Korea. Hauptthemen laut MEDLINE: Dog Diseases, Lacerations. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare tear film (TF) osmolarity measured using TearLab® and I‐PEN® osmometers in the same dogs without any ocular surface disease. Animal Studied Fifty‐two dogs (98 eyes) of different breeds were evaluated. Procedures Tear film (TF) osmolarity was evaluated at 2‐min intervals. The test was randomly determined, and single measurements were performed using each osmometer. Subsequently, complete ophthalmologic examinations were performed based on Schirmer tear test‐1 (STT‐1) analysis, tear film breakup time (TFBUT), and slit‐lamp biomicroscopy. For each osmometer, the mean ± standard deviation of the TF osmolarity was calculated, and a paired Student's t ‐test was used to compare the values obtained. Pearson correlation analysis was performed to assess the association between osmolarity and other values such as STT‐1, TFBUT, and age.

Results

Tear film osmolarity determined using TearLab® (340.42 ± 15.87 mOsm/L) and I‐PEN® (321.58 ± 17.39 mOsm/L) were significantly different ( p < .001). However, statistical significance could not be confirmed between osmolarity and other values, such as STT‐1, TFBUT, and age.

Conclusions

In dogs, the TF osmolarity values obtained using TearLab® tend to be higher than those obtained using I‐PEN®, contrary to that observed in humans. These findings can serve as a reference for establishing normal values for each osmometer for clinical use in measuring TF osmolarity in dogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dog DiseasesLacerationsAnimalsDogsEyeOsmolar ConcentrationOsmometrySlit Lamp MicroscopyTears

Stichwörter der Autor:innen

dry eyeevaporative dry eyeocular surface diseasequalitative tear film deficiencyrandomized comparisontear film osmolarity

Autor:innen und Institutionen

  • Department of Veterinary Ophthalmology, College of Veterinary Medicine, Konkuk University, Seoul, Korea.
  • KU Center for Animal Blood Medical Science, Konkuk University, Seoul, Korea.

ORCID-Profile: Hyun-Wook Kim, Joon-Young Kim

Zitieren

APA

Kim, H. W., & Kim, J. Y. (2023). Randomized comparison of in vivo performance of TearLab ® and I‐PEN ® osmometry in normal dogs. Veterinary Ophthalmology. https://doi.org/10.1111/vop.13140

Vancouver

Kim HW, Kim JY. Randomized comparison of in vivo performance of TearLab ® and I‐PEN ® osmometry in normal dogs. Veterinary Ophthalmology. 2023. doi:10.1111/vop.13140

BibTeX
@article{Kim2023,
  author = {Kim, Hyun-Wook and Kim, Joon-Young},
  title = {Randomized comparison of in vivo performance of TearLab ® and I‐PEN ® osmometry in normal dogs},
  journal = {Veterinary Ophthalmology},
  year = {2023},
  doi = {10.1111/vop.13140}
}
Kostenlos starten →