Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats
Journal of Veterinary Emergency and Critical Care · 2024
DOI: 10.1111/vec.13438 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Veterinary Emergency and Critical Care, 2024. Verfasst von G Santarelli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Animal Medicine and Surgery, Veterinary Faculty, University of Murcia, Murcia, Spain. Hauptthemen laut MEDLINE: Troponin I, Cat Diseases, Dog Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Objectives
(1) To compare the results of a rapid test for qualitative detection of cardiac troponin I (cTnI) values >1 ng/mL with those obtained using a reference quantitative method and (2) to perform a semiquantitative assessment of rapid test results using this point‐of‐care (POC) assay.
Design
Prospective cross‐sectional study from April 2015 to November 2020.
Setting
Secondary referral hospital. Animals Eighty dogs and 20 cats, with and without cardiovascular disease.
Interventions
None. Measurements and Main Results Serum samples were obtained, and cTnI rapid test was conducted in parallel with chemiluminescence assay (reference standard). Positive results from the rapid test were further classified as mild and strong positives, based on subjective assessment of the color intensity of the test line. Rapid test was deemed valid in all patients. There was agreement for positive samples between the qualitative and quantitative techniques in 31 dogs and 5 cats, and for negative samples in 43 dogs and 13 cats, resulting in a strong and moderate agreement, respectively. There was a significant difference between color scale groups.
Conclusions
The rapid test assessed provides a feasible POC option to determine concentrations of cTnI >1 ng/mL in dogs and cats and shows a moderate to strong agreement with a validated conventional quantitative assay. Furthermore, semiquantitative assessment allows estimation of the magnitude of the elevation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Animal Medicine and Surgery, Veterinary Faculty, University of Murcia, Murcia, Spain.
- Department of Biotechnology, Instituto Murciano de Investigación y Desarrollo Agrario y Alimentario, Murcia, Spain.
ORCID-Profile: G Santarelli
Zitieren
APA
Santarelli, G., Sebastián Marcos, P., Talavera, J., Aznar-Cervantes, S. D., & Fernández Del Palacio, J. (2024). Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats. Journal of Veterinary Emergency and Critical Care. https://doi.org/10.1111/vec.13438
Vancouver
Santarelli G, Sebastián Marcos P, Talavera J, Aznar-Cervantes SD, Fernández Del Palacio J. Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats. Journal of Veterinary Emergency and Critical Care. 2024. doi:10.1111/vec.13438
BibTeX
@article{Santarelli2024,
author = {Santarelli, G and Sebastián Marcos, P and Talavera, J and Aznar-Cervantes, S D and Fernández Del Palacio, J},
title = {Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats},
journal = {Journal of Veterinary Emergency and Critical Care},
year = {2024},
doi = {10.1111/vec.13438}
}
EUVIMED