EUVIMEDEUVIMED entdecken
Evaluationsstudie

Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats

G Santarelli iD, P Sebastián Marcos, J Talavera, S D Aznar-Cervantes, J Fernández Del Palacio

Journal of Veterinary Emergency and Critical Care · 2024

DOI: 10.1111/vec.13438 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Veterinary Emergency and Critical Care, 2024. Verfasst von G Santarelli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Animal Medicine and Surgery, Veterinary Faculty, University of Murcia, Murcia, Spain. Hauptthemen laut MEDLINE: Troponin I, Cat Diseases, Dog Diseases. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

(1) To compare the results of a rapid test for qualitative detection of cardiac troponin I (cTnI) values >1 ng/mL with those obtained using a reference quantitative method and (2) to perform a semiquantitative assessment of rapid test results using this point‐of‐care (POC) assay.

Design

Prospective cross‐sectional study from April 2015 to November 2020.

Setting

Secondary referral hospital. Animals Eighty dogs and 20 cats, with and without cardiovascular disease.

Interventions

None. Measurements and Main Results Serum samples were obtained, and cTnI rapid test was conducted in parallel with chemiluminescence assay (reference standard). Positive results from the rapid test were further classified as mild and strong positives, based on subjective assessment of the color intensity of the test line. Rapid test was deemed valid in all patients. There was agreement for positive samples between the qualitative and quantitative techniques in 31 dogs and 5 cats, and for negative samples in 43 dogs and 13 cats, resulting in a strong and moderate agreement, respectively. There was a significant difference between color scale groups.

Conclusions

The rapid test assessed provides a feasible POC option to determine concentrations of cTnI >1 ng/mL in dogs and cats and shows a moderate to strong agreement with a validated conventional quantitative assay. Furthermore, semiquantitative assessment allows estimation of the magnitude of the elevation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Troponin ICat DiseasesDog DiseasesDogsAnimalsCatsCross-Sectional StudiesProspective StudiesMaleFemalePoint-of-Care SystemsPoint-of-Care TestingCardiovascular Diseases

Stichwörter der Autor:innen

diagnosticsemergencymyocardial damagemyocardial injury

Substanzen

Troponin I

Autor:innen und Institutionen

  • Department of Animal Medicine and Surgery, Veterinary Faculty, University of Murcia, Murcia, Spain.
  • Department of Biotechnology, Instituto Murciano de Investigación y Desarrollo Agrario y Alimentario, Murcia, Spain.

ORCID-Profile: G Santarelli

Zitieren

APA

Santarelli, G., Sebastián Marcos, P., Talavera, J., Aznar-Cervantes, S. D., & Fernández Del Palacio, J. (2024). Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats. Journal of Veterinary Emergency and Critical Care. https://doi.org/10.1111/vec.13438

Vancouver

Santarelli G, Sebastián Marcos P, Talavera J, Aznar-Cervantes SD, Fernández Del Palacio J. Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats. Journal of Veterinary Emergency and Critical Care. 2024. doi:10.1111/vec.13438

BibTeX
@article{Santarelli2024,
  author = {Santarelli, G and Sebastián Marcos, P and Talavera, J and Aznar-Cervantes, S D and Fernández Del Palacio, J},
  title = {Evaluation of a rapid test for point‐of‐care detection of cardiac troponin I in serum of healthy and diseased dogs and cats},
  journal = {Journal of Veterinary Emergency and Critical Care},
  year = {2024},
  doi = {10.1111/vec.13438}
}
Kostenlos starten →