The effect of storage at 4°C on canine‐specific albumin on product sterility and albumin concentration
Journal of Veterinary Emergency and Critical Care · 2021-09 · 31 (5) · 574-577
DOI: 10.1111/vec.13090 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Veterinary Emergency and Critical Care, online erschienen am 23.07.2021. Verfasst von Alicia Mastrocco und 2 weiteren Autor:innen. Beteiligte Einrichtung: Section of Emergency and Critical Care, The Animal Medical Center, New York, New York, USA. Hauptthemen laut MEDLINE: Dog Diseases, Infertility. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Objectives
To determine if lyophilized canine‐specific albumin (CSA) can be stored beyond the manufacturer recommended 6 hours post‐reconstitution without significant concern for bacterial growth.
Design
Laboratory research.
Setting
Large private teaching hospital.
Interventions
Six bottles of lyophilized CSA were retrieved from a medical grade (4°C) refrigerator and were reconstituted with 0.9% NaCl to a 5% solution. Time to complete dissolution of all bottles at room temperature without agitation was recorded in minutes. A 1.5‐mL sample was collected from each bottle at the following time points: time 0 (at the time of complete dissolution), and then 6, 12, and 24 hours after removal from 4°C. Each aliquot was inoculated into a blood culture tube and was immediately submitted for aerobic and anaerobic bacterial culture. A positive and negative control were cultured at the 24‐hour time point. At each time point, an additional 0.5‐mL aliquot from each albumin bottle was collected, and these were combined to determine the average albumin concentration (g/L, g/dL) as measured by an in‐house analyzer. The albumin was stored at 4°C between sample collection. Measurements and Main Results The reconstitution of CSA and storage at 4°C for up to 24 hours did not result in anaerobic or aerobic bacterial growth in any of the 24 cultured samples. Storage did not have a clinically significant effect on the albumin concentration of the solution. The average albumin concentration of all samples was 42 g/L (4.2 g/dL). No growth was noted in the negative control, and the positive control grew 4 strains of bacteria.
Conclusions
It appears safe to use lyophilized CSA up to 24 hours post‐reconstitution without significant risk of bacterial growth or change in albumin concentration.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Section of Emergency and Critical Care, The Animal Medical Center, New York, New York, USA.
ORCID-Profile: Alicia Mastrocco, Dava Cazzolli, Jennifer Prittie
Zitieren
APA
Mastrocco, A., Cazzolli, D., & Prittie, J. (2021). The effect of storage at 4°C on canine‐specific albumin on product sterility and albumin concentration. Journal of Veterinary Emergency and Critical Care, 31(5), 574-577. https://doi.org/10.1111/vec.13090
Vancouver
Mastrocco A, Cazzolli D, Prittie J. The effect of storage at 4°C on canine‐specific albumin on product sterility and albumin concentration. Journal of Veterinary Emergency and Critical Care. 2021;31(5):574-577. doi:10.1111/vec.13090
BibTeX
@article{Mastrocco2021,
author = {Mastrocco, Alicia and Cazzolli, Dava and Prittie, Jennifer},
title = {The effect of storage at 4°C on canine‐specific albumin on product sterility and albumin concentration},
journal = {Journal of Veterinary Emergency and Critical Care},
year = {2021},
volume = {31},
number = {5},
pages = {574--577},
doi = {10.1111/vec.13090}
}
EUVIMED