Evaluationsstudie in der Zeitschrift Veterinary Clinical Pathology, 2026. Verfasst von Rose D Nolen-Walston und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies-New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Adiponectin, Immunoturbidimetry. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Laminitis Research Fund, University of Pennsylvania.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Total adiponectin (TA) is a marker of metabolic health in equids, with values below a critical decision point of < 7.9 μg/mL conferring increased risk of laminitis.

Objectives

To evaluate an IT assay to measure serum [TA] in equids and to assess its correlation with [high molecular weight adiponectin] (HMWA) measured by ELISA.

Methods

Total serum adiponectin concentrations from 207 adult horses were measured using both an IT assay for TA and HMWA using a previously validated ELISA assay. Data were analyzed using Spearman correlation and Passing‐Bablok regression. Intra‐ and inter‐assay precision, linearity, lower limit of quantification (LLoQ), and freeze–thaw stability were assessed for the [TA] assay.

Results

Mean (range) intra‐assay coefficient of variation (CV%) was 2.3% (1.8%–2.8%); inter‐assay, across‐day CV% was 3.3% (3.25%–3.4%), and across reagent lot CV was 11.7% (9.0%–17.9%). Mean recovery upon dilution was 133.7% (122.6%–140.6%), and LLoQ 1.3 μg/mL. The median CV for 5 freeze–thaw cycles was 3.0% (range 1.0%–3.0%) with a median change in concentration of −11% (range −[9.9–17.1]%). A strong correlation between [TA] and [HMWA] is observed ( ρ = 0.90 [95% confidence interval 0.86–0.92], p < 0.001), although in 18% of samples, [HMWA] > [TA].

Conclusions

The turbidimetric immunoassay is sufficiently precise and reliable for measurement of [TA] in equids, especially around the critical decision point, and LLoQ was below the lowest clinical cut‐off value. [TA] overall correlated well with [HMWA] in this population, although instances of higher [HMWA] than [TA] were noted at high [HMWA].

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdiponectinImmunoturbidimetryAnimalsHorsesEnzyme-Linked Immunosorbent AssayReproducibility of ResultsBiomarkersFemaleMale

Stichwörter der Autor:innen

endocrinopathyequine metabolic syndromehorseinsulin dysregulationlaminitis

Substanzen

AdiponectinBiomarkers

Autor:innen und Institutionen

  • Department of Clinical Studies-New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.

ORCID-Profile: Rose D Nolen-Walston, Daniela Luethy, Darko Stefanovski, Andrew W Van Eps

Förderung

  • the Laminitis Research Fund, University of Pennsylvania

Zitieren

APA

Nolen-Walston, R. D., Lowndes, C. R., Kulp, J. C., Luethy, D., Stefanovski, D., & Van Eps, A. W. (2026). Evaluation of an Immunoturbidometric Assay for Measurement of Total Adiponectin Concentration in Equine Serum Samples. Veterinary Clinical Pathology. https://doi.org/10.1111/vcp.70118

Vancouver

Nolen-Walston RD, Lowndes CR, Kulp JC, Luethy D, Stefanovski D, Van Eps AW. Evaluation of an Immunoturbidometric Assay for Measurement of Total Adiponectin Concentration in Equine Serum Samples. Veterinary Clinical Pathology. 2026. doi:10.1111/vcp.70118

BibTeX
@article{NolenWalston2026,
  author = {Nolen-Walston, Rose D and Lowndes, Caitrin R and Kulp, Jeaneen C and Luethy, Daniela and Stefanovski, Darko and Van Eps, Andrew W},
  title = {Evaluation of an Immunoturbidometric Assay for Measurement of Total Adiponectin Concentration in Equine Serum Samples},
  journal = {Veterinary Clinical Pathology},
  year = {2026},
  doi = {10.1111/vcp.70118}
}
Kostenlos starten →