Comparison of Three Feline Crossmatch Methods—Tube, Gel Column, and Immunochromatographic Strip
Veterinary Clinical Pathology · 2025
DOI: 10.1111/vcp.70039 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Clinical Pathology, 2025. Verfasst von Victoria K DiCiccio und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences and Advanced Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. Hauptthemen laut MEDLINE: Blood Grouping and Crossmatching, Chromatography, Affinity. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
A pre‐transfusion blood crossmatch is recommended to ensure RBC compatibility for previously transfused and transfusion‐naïve cats.
Objectives
To compare 3 crossmatch methods and anti‐feline globulin (AFG) enhancement for determining RBC compatibility.
Methods
Prospective study. Major crossmatches were performed using serum from 68 “recipient” cats and RBCs from 44 “donor” cats. Crossmatch methods evaluated include laboratory tube and gel column without and with AFG enhancement and an in‐clinic AFG‐enhanced immunochromatographic strip.
Results
Tube and gel crossmatches were performed for 211 and strip crossmatches for 133 recipient‐donor pairs. RBC incompatibilities were noted in at least 1 crossmatch method for 123 recipient‐donor pairs. For determination of the degree of incompatibility, there was a correlation between standard and AFG‐enhanced crossmatches for both tube and gel ( p < 0.001), standard tube and gel ( p = 0.002), and AFG‐enhanced tube and gel ( p < 0.001). Twelve of 46 and 22 of 113 recipient‐donor pairs deemed incompatible with tube and gel, respectively, had RBC agglutination noted only with the addition of AFG. RBC incompatibilities were noted on 15 strips, 4 of which were type A‐B mismatched. Odds of detecting RBC incompatibility using strip were 2.9 ( p = 0.001) and 6.1 ( p < 0.001) times greater with each unit increase in the degree of incompatibility detected by standard and AFG‐enhanced tube, respectively.
Conclusions
The clinical relevance of any observed RBC incompatibilities, other than known A‐B mismatches, is unknown. While the strip crossmatch is simple to perform and interpret, it might not be sufficiently sensitive to detect weaker RBC incompatibilities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Clinical Sciences and Advanced Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
ORCID-Profile: Mary Beth Callan
Zitieren
APA
DiCiccio, V. K., Hess, R. S., Weinstein, N. M., Fromm, S., Gonzalez, R., Marryott, K., & Callan, M. B. (2025). Comparison of Three Feline Crossmatch Methods—Tube, Gel Column, and Immunochromatographic Strip. Veterinary Clinical Pathology. https://doi.org/10.1111/vcp.70039
Vancouver
DiCiccio VK, Hess RS, Weinstein NM, Fromm S, Gonzalez R, Marryott K, et al. Comparison of Three Feline Crossmatch Methods—Tube, Gel Column, and Immunochromatographic Strip. Veterinary Clinical Pathology. 2025. doi:10.1111/vcp.70039
BibTeX
@article{DiCiccio2025,
author = {DiCiccio, Victoria K and Hess, Rebecka S and Weinstein, Nicole M and Fromm, Samantha and Gonzalez, Ruth and Marryott, Kimberly and Callan, Mary Beth},
title = {Comparison of Three Feline Crossmatch Methods—Tube, Gel Column, and Immunochromatographic Strip},
journal = {Veterinary Clinical Pathology},
year = {2025},
doi = {10.1111/vcp.70039}
}