Discrepancies of bovine haptoglobin concentrations between serum and plasma using two different anticoagulants and a colorimetric assay based on peroxidase activity
Veterinary Clinical Pathology · 2024
DOI: 10.1111/vcp.13386 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Veterinary Clinical Pathology, 2024. Verfasst von R Schmitt und 1 weiteren Autor:innen. Beteiligte Einrichtung: Ruminant and Swine Clinic, Free University of Berlin, Berlin, Germany. Hauptthemen laut MEDLINE: Haptoglobins, Colorimetry, Anticoagulants, Cattle Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Haptoglobin (Hp) is an emerging diagnostic marker in cattle, and knowledge of suitable sample types and measurement methods is important.
Objectives
The aims of this study were to compare the results of a colorimetric assay (CA) and an ELISA for bovine Hp using serum, EDTA plasma, and lithium‐heparinized (LH) plasma, respectively, and to assess the diagnostic potential for puerperal metritis.
Methods
In experiment 1, Hp was measured in pooled aliquots of serum ( n = 10), EDTA plasma ( n = 10), and LH plasma ( n = 10) of 100 healthy fresh lactating dairy cows from 10 farms using both the CA and the ELISA. In experiment 2, five healthy and five cows with acute puerperal metritis were sampled, and Hp was determined using both assays for all three sample types. In experiment 3, aliquots of serum and LH plasma from cows in different lactation stages were transferred into plain, EDTA‐coated, and LH‐coated tubes and mixed before colorimetric analyses. Distilled water was also placed into each tube type and treated similarly.
Results
Plasma samples measured with the CA showed on average 2.3 (EDTA) and 2.5 (LH) times higher Hp concentrations compared with serum, whereas no differences were seen with the ELISA results between sample types. Based on a clinical cut‐off value, both methods differentiated sick from healthy cows. Haptoglobin measurements with the ELISA were less precise compared with CA measurements due to high dilutions. No influence of the anticoagulants on the CA was observed.
Conclusions
Due to measurement discrepancies between serum and plasma, CAs for bovine Hp based on peroxidase activity should be performed with serum, or specific reference ranges for plasma samples should be established. In this study, CA results obtained with LH plasma were more precise than results obtained with EDTA plasma. Both the CA and the ELISA are suitable diagnostic tools for the diagnosis of puerperal metritis, but CA measurements were more precise in this study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Ruminant and Swine Clinic, Free University of Berlin, Berlin, Germany.
ORCID-Profile: R Schmitt, R Staufenbiel
Zitieren
APA
Schmitt, R., & Staufenbiel, R. (2024). Discrepancies of bovine haptoglobin concentrations between serum and plasma using two different anticoagulants and a colorimetric assay based on peroxidase activity. Veterinary Clinical Pathology. https://doi.org/10.1111/vcp.13386
Vancouver
Schmitt R, Staufenbiel R. Discrepancies of bovine haptoglobin concentrations between serum and plasma using two different anticoagulants and a colorimetric assay based on peroxidase activity. Veterinary Clinical Pathology. 2024. doi:10.1111/vcp.13386
BibTeX
@article{Schmitt2024,
author = {Schmitt, R and Staufenbiel, R},
title = {Discrepancies of bovine haptoglobin concentrations between serum and plasma using two different anticoagulants and a colorimetric assay based on peroxidase activity},
journal = {Veterinary Clinical Pathology},
year = {2024},
doi = {10.1111/vcp.13386}
}
EUVIMED