Analytical errors in nucleated red blood cell enumeration
Veterinary Clinical Pathology · 2023
DOI: 10.1111/vcp.13224 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Clinical Pathology, 2023. Verfasst von Juliet E Brown und 2 weiteren Autor:innen. Beteiligte Einrichtung: U-Vet Werribee Animal Hospital and Faculty of Veterinary and Agricultural Science, University of Melbourne, Werribee, Victoria, Australia. Hauptthemen laut MEDLINE: Cat Diseases, Dog Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Enumeration of nucleated red blood cells (NRBCs) in peripheral blood of dogs and cats is performed by manual counting during blood film evaluation. Automated methods have increased precision and accuracy; however, most analyzers cannot distinguish leukocytes and NRBCs. The Sysmex XN‐V Series may distinguish NRBCs and leukocytes; however, analytical errors occur.
Objectives
We aimed to investigate cases with discrepant automated and manual NRBC counts, and to evaluate reasons for analytical errors.
Methods
Data from samples with increased NRBCs were collected retrospectively and compared with manual counts performed on blood films using Spearman's correlation, Passing‐Bablok agreement analysis, and Bland–Altman comparisons. Precision of the automated method and interobserver agreement of manual counts were evaluated. Cases with discrepant results were investigated.
Results
Agreement between the methods was good at ≤1NRBC ×10 9 /L in dogs and cats, and inadequate at ≥1NRBC ×10 9 /L. The automated method demonstrated a negative proportional difference to the manual method. Precision was good for the automated method (overall CV 7.1%) and interobserver agreement for the manual method was poor overall (mean CV 27.3%, range 0%‐106.1%). Inaccuracies in NRBC enumeration by the automated method occurred with high hematocrits, the mergence of the cell fragments and leukocyte clouds, and the presence of earlier erythroid precursors.
Conclusions
NRBC enumeration by the WNR channel on the Sysmex XN‐1000 V is precise and has good agreement with manual counts in canine and feline blood samples at ≤1NRBC ×10 9 /L. Manual film review is indicated for samples with ≥1NRBC ×10 9 /L, earlier erythroid precursors, samples from greyhounds and dehydrated patients, and if gating errors are noted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- U-Vet Werribee Animal Hospital and Faculty of Veterinary and Agricultural Science, University of Melbourne, Werribee, Victoria, Australia.
ORCID-Profile: Juliet E Brown, Astrid Oscos-Snowball
Zitieren
APA
Brown, J. E., Oscos-Snowball, A., & Courtman, N. F. (2023). Analytical errors in nucleated red blood cell enumeration. Veterinary Clinical Pathology. https://doi.org/10.1111/vcp.13224
Vancouver
Brown JE, Oscos-Snowball A, Courtman NF. Analytical errors in nucleated red blood cell enumeration. Veterinary Clinical Pathology. 2023. doi:10.1111/vcp.13224
BibTeX